13. Program Support Functions
(6) When tool life management data is registered with G10 command after group No. is
designated.
#60000 = 10 ; ..............Designates the group No.
G10 L3 ; .......................Starts the life management data registration.
P10 LLn NNn ; ............10 is the group No., Ln is the life per tool,
TTn ; ............................Tn is the tool No.
:
G11 ; ...........................Registers the group 10 data with the G10
#111 = #61001 ; ..........Reads the group 10, #1 tool No.
G10 L3 ; .......................Starts the life management data registration.
P1 LLn NNn ; ..............1 is the group No., Ln is the life per tool,
TTn ; ............................Tn is the tool No.
:
G11 ; ............................Registers the life data with the G10
#111 = 61001 ; ............Group 10 does not exist. #201 = –1.
Precautions for tool life management
(1) If the tool life management system variable is commanded without designating a group No.,
the data of the group registered at the head of the registered data will be read.
(2) If a non-registered group No. is designated and the tool life management system variable is
commanded, "-1" will be read as the data.
(3) If an unused registration No. tool life management system variable is commanded, "-1" will be
read as the data.
(4) Once commanded, the group No. is valid until NC reset.
13.5 User macro specifications
Nn is the method.
command.
Nn is the method.
command.
(The registered data is deleted.)
218
The group 10 life data
is registered.
The life data other than
group 10 is registered.