ICP-CC408 | Installation Guide | 6.0
5.5.2
Disarming from AWAY Mode
Press and hold either [AWAY] or [STAY] for 2 sec.
Two beeps sound on the remote codepad and the
AWAY indicator is extinguished.
If horn speaker indication beeps are enabled, one
beep sounds from the horn speaker. If strobe
indications are enabled, the strobe flashes for 3 sec to
indicate the system is disarmed.
5.5.3
Arming in STAY Mode 1
Press and hold STAY for 2 sec.
Two beeps sound on the remote codepad and the
STAY indicator lights. Exit Time starts.
If horn speaker indication beeps are enabled, one
two-tone beep sounds from the horn speaker. If
strobe indications are enabled, the strobe flashes for
6 sec to indicate the system is armed.
5.5.4
Disarming from STAY Mode 1
Press and hold either [AWAY] or [STAY] for 2 sec.
Two beeps sound on the remote codepad and the
STAY indicator is extinguished.
If horn speaker indication beeps are enabled, one
beep sounds from the horn speaker. If strobe
indications are enabled, the strobe flashes for 3 sec to
indicate the system is disarmed.
5.5.5
Panic Alarm
Press and hold [AWAY] and [STAY] together for 2
sec.
An audible Panic Alarm is initiated that activates the
horn speaker, strobe, and internal sirens.
If Option 1 is selected in Location 425
(refer to Section 18.2 System Options 2
on page 79), the remote radio Panic
Alarm is also silent.
5.5.6
Remote Outputs
The [DOOR] and [AUX] buttons on the 4-channel
hand-held transmitter can operate two remote
outputs. Only the installer can program these
outputs. You can use the Output Event Types listed
in Table 22. Refer Section 16.0 Programmable Outputs
on page 68 for more information.
Table 22: Remote Output Event Types
Output
Event Type
Description
2,11
Radio Control Output 1
2,12
Radio Control Output 2
2,13
Radio Control Output 1 – not
armed in AWAY Mode
2,14
Radio Control Output 2 – not
armed in AWAY Mode
Bosch Security Systems, Inc. | 12/08 | F01U089463-02
System Functions
To turn Output 1 on:
Press and hold [DOOR] for 2 sec.
Output 1 turns on.
To turn Output 1 off:
Press and hold [DOOR] for 2 sec.
Output 1 turns off.
To turn Output 2 on:
Press and hold [AUX] for 2 sec.
Output 2 turns on.
To turn Output 2 off:
Press and hold [AUX] for 2 sec.
Output 2 turns off.
All reset times for the [DOOR] and [AUX]
buttons are referenced to Polarities 1 and
8. Reset times vary depending on the
polarity used.
6.0 System Functions
This section explains more advanced features, such
as Installer Code, Master Code, and hold-down
functions that are required for testing and regular
maintenance of the system.
6.1
Installer Code Functions
Installer Code functions allow the installer to perform
various system tests and tasks without knowing a
Master Code.
To access the required Installer Code function, enter
the Installer Code and corresponding function digit,
and press [AWAY]. The Installer Code functions are
listed in Table 23.
You can access these functions only when the system
is disarmed.