Bosch ICP-CC408 Installation Manual page 102

Table of Contents

Advertisement

ICP-CC408 | Installation Guide | 24.0
Codepad Medical Report
341 to 342
Location
Default
Codepad Reporting Options
343
Location
0
No report required
1
Receiver 1
2
Receiver 2
4
Receiver 1 and 2
8
Receiver 2 only when Receiver 1 fails
System Status – AUX Power Supply Fail Report
344 to 345
Location
Default
System Status – AUX Power Supply Fail Restore
Report
346 to 347
Location
Default
System Status – AC Fail Report
348 to 349
Location
Default
System Status – AC Fail Restore Report
350 to 351
Location
Default
System Status – Low Battery Report
352 to 353
Location
Default
System Status – Low Battery Restore Report
354 to 355
Location
Default
System Status – Access Denied
356 to 358
Location
Default
Location 356
Code retries
Location 357
Reporting code – tens digit
Location 358
Reporting code – units digit
System Status Reporting Options
359
Location
0
No report required
1
Receiver 1
2
Receiver 2
4
Receiver 1 and 2
8
Receiver 2 only when Receiver 1 fails
Test Reporting Time
Location
360 to 366
Default
Location 360
Hour of the day – tens digit
Location 361
Hour of the day – units digit
Location 362
Minute of the day – tens digit
Location 363
Minute of the day – units digit
Location 364
Test Report code – tens digit
Location 365
Test Report code – units digit
Location 366
Repeat interval in days
Bosch Security Systems, Inc. | 12/08 | F01U089463-02
Programming Sheets
Test Reporting Dialer Options
Location
Refer to page 66
0
7 13
1
2
Refer to page 66
4
8
Output Configurations
Location
Output 1
Default for horn speaker
Output 2
Refer to page 66
Default for Fire Alarm
10 3
verification
Strobe
Default for strobe (reset in 8 hr)
Refer to page 66
Relay
10 8
Default for sirens running
Codepad
Default for entry/Exit Warning
Refer to page 66
and Delay Alarm
10 2
Outputs are programmed with four parameters in six
locations:
Refer to page 66
Event Type
10 7
Entry Time 1
Refer to page 67
Location
10 1
Default
Location 398
Refer to page 67
Location 399
10 6
Entry Time 2
Location
Refer to page 67
Default
Location 400
6 7 12
Location 401
Exit Time
Location
Default
Refer to page 67
Location 402
Location 403
Entry Guard Time for STAY Mode
Location
Default
Location 404
Location 405
Refer to page 67
Delay Alarm Reporting Time
0 0 0 0 7 1 0
Location
Default
Location 406
Location 407
367
No report required
Receiver 1
Receiver 2
Receiver 1 and 2
Receiver 2 only when Receiver 1 fails
368 to 397
Locations 368 to 373
Locations 374 to 379
Locations 380 to 385
Locations 386 to 391
Locations 392 to 397
Polarity
Time Base
398 to 399
Increments of 1 sec (0 to 15 sec)
Increments of 16 sec (0 to 240 sec)
400 to 401
Increments of 1 sec (0 to 15 sec)
Increments of 16 sec (0 to 240 sec)
402 to 403
Increments of 1 sec (0 to 15 sec)
Increments of 16 sec (0 to 240 sec)
404 to 405
Increments of 1 sec (0 to 15 sec)
Increments of 16 sec (0 to 240 sec)
406 to 407
Increments of 1 sec (0 to 15 sec)
Increments of 16 sec (0 to 240 sec)
EN | 102
Refer to page 68
Refer to page 68
1 14 0 0 0 0
2 7 10 2 1 5
2 0 6 4 0 8
1 15 1 0 0 0
0 13 2 1 0 1
Time Multiplier
Refer to page 76
4 1
Refer to page 76
8 2
Refer to page 76
12 3
Refer to page 76
0 0
Refer to page 76
0 0