The Installer Code provides access only to the
Installer's Programming Mode and does not allow
you to arm and disarm the system. You cannot enter
Installer's Programming Mode when the system is
armed, or at any time during siren run time.
You can program the ICP-CC408 Control Panel
using any of these two devices:
Remote codepad
CC816 Alarm Link Upload/Download Software
2.1
Programming with the Remote
Codepad
To program the control panel using the remote
codepad, the system must be disarmed with no alarm
memory present.
To access Installer's Programming Mode:
Enter the four-digit Installer Code (the factory default
is 1234) and press [AWAY].
Two beeps sound and both the AWAY and the
STAY indicators flash simultaneously to indicate that
you entered Installer's Programming Mode.
When you enter Installer's Programming Mode, you
are automatically positioned at Location 000, the first
digit of the Primary Telephone Number for
Receiver 1. The codepad indicators display the
current data stored in this location.
Table 3:

Codepad Indicators

Data
Zone Indicators
Value
1
2
3
0
1
X
2
X
3
X
4
5
6
7
8
9
X
10
11
X
12
X
13
X
14
15
To move to a different programming location:
Enter the location number and press [AWAY].
For example, press [3 4][AWAY] to automatically
step you to the beginning of the Subscriber ID
Number for Receiver 1. The data stored in the new
location appears.
Bosch Security Systems, Inc. | 12/08 | F01U089463-02
4
5
6
7
8
MAINS
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Programming
To move to the next location:
Press [AWAY].
For example, if you are currently positioned at
Location 034, press [AWAY] to step to Location 035.
To move to the previous location:
Press [STAY].
For example, if you are positioned at Location 035,
press [STAY] to step back to Location 034.
To change data in the current location:
Enter the new value (0 to 15) and press [STAY].
The data is stored and you remain positioned at the
same location. The codepad indicators display the
new value (for example, if you enter [1 4] and press
[STAY], the Zone 4 and MAINS indicators are lit).
To exit from Installer's Programming Mode:
Enter command [9 6 0] and press [AWAY].
Two beeps sound and the STAY and AWAY
indicators are extinguished. The system returns to the
disarmed state and is now ready for use.
Refer to Section 2.4 Installer's Programming Commands
on page 11 for more information about using
Installer's Programming Mode.
2.2
Programming with the
Programming Key
The CC891 Programming Key allows you to store or
copy programming information from your control
panel. After storing information in the programming
key, you can easily program other ICP-CC408
Control Panels with the same programming data.
You can also use the programming key to back up
existing information.
If you connect the programming key to the control
panel when it is disarmed, the key automatically
initiates a data transfer to the control panel's
memory.
If you have a new programming key, enter Installer's
Programming Mode, program the system as required,
and connect the programming key to the control
panel.
To connect the programming key:
Locate the socket labeled PROGRAMMING KEY at
the top of the printed circuit board (PCB) next to the
Auxiliary Module socket. Observe the triangular
markings on the PCB and align them with the
markings on the programming key.
To copy data from the control panel data to the
programming key:
1. Enter the Installer Code (the default is 1234) and
press [#] to enter Installer's Programming Mode.
2. Enter [9 6 2 #].
Refer to Section 2.4.4 Command 962 – Copy the
Control Panel Memory to the Programming Key on
page 12 for more information.