ICP-CC408 | Installation Guide | 5.0
To determine which receiver failed to report:
1. In Fault Analysis Mode, press and hold [8].
Two beeps sound.
2. Release the button.
If Receiver 1 failed to report, the Zone 1
indicator lights. If Receiver 2 failed to report, the
Zone 2 indicator lights.
If the primary and secondary telephone numbers for
Receiver 1 or Receiver 2 are set up for base
reporting, Receiver 1 and Receiver 2 can each
attempt up to twelve calls, per event, to the base
station receiver. If the primary and secondary
telephone numbers are programmed for both
Receiver 1 and Receiver 2, the two receivers together
can attempt up to 24 calls if the event is allocated to
report on both receivers.
The control panel attempts to call the base station
receiver up to six times using both the primary
secondary telephone numbers (three times if only the
primary telephone number is programmed). If the
control panel fails to communicate to the base station
receiver, a communications fault occurs. The control
panel waits 10 min before it attempts to report to the
base station receiver up to six more times. The
communication fault is reset after the next successful
call attempt.
If Receiver 1 or Receiver 2 is set up for
domestic reporting, the control panel
does not display a fault if it fails to report
after the maximum of six call attempts.
If Option 1 in Location 145 is enabled
(refer to Section 12.1 Dialer Options 1 on
page 53) and no telephone numbers are
programmed, no fault is registered.
AC MAINS Failure
An AC MAINS supply failure automatically flashes
the MAINS indicator. If the AC MAINS supply is
disconnected continuously for longer than 2 min, the
remote codepad beeps the codepad buzzer once per
min. If the control panel is programmed to report an
AC MAINS failure to a base station receiver, an AC
Fail Report (Contact ID Event Code 301) is
transmitted.
The MAINS indicator stops flashing when the AC
MAINS supply is reconnected. When the AC
MAINS supply is connected continuously for 2 min,
the codepad stops the once per min beep and an AC
Fail Restore Report is transmitted to the base station
receiver.
If the Enable AC Fail in 1 Hour option (1) is selected
in Location 426 (refer to Section 18.3 System Options 3
on page 79), the codepad flashes the MAINS
indicator when the AC MAINS supply is
disconnected, but does not activate the dialer or the
codepad buzzer unless the AC MAINS supply is
disconnected continuously for 1 hour.
Bosch Security Systems, Inc. | 12/08 | F01U089463-02

Remote Radio Transmitter Operations

If the Ignore AC MAINS Fail option (2) is selected in
Location 426 (refer to Section 18.3 System Options 3 on
page 79), the codepad does not indicate when the
AC MAINS supply fails, but the control panel still
reports an AC Fail Report, if enabled.
5.0 Remote Radio Transmitter

Operations

The ICP-CC408 Control Panel can be remotely
operated using hand-held remote radio transmitters.
You can use either a 2-channel or a 4-channel hand-
held transmitter to operate the system.
Both the 2-channel and 4-channel hand-held
transmitters can remotely arm and disarm the system
in AWAY Mode or STAY Mode 1, and can activate
remote Panic Alarms. The 4-channel hand-held
transmitter has the added ability to operate the
control panel's programmable outputs to activate a
garage door or outside lights, for example.
Before a hand-held radio transmitter can operate the
control panel, you must teach the transmitter's radio
code to the control panel. Refer to Section 5.3
Changing or Deleting Remote Radio User Codes on page
26 for more information.
5.1
Indications from Remote Radio
Transmitter Operations
When using the 2-channel or 4-channel hand-held
transmitter to operate the system, audible or visual
indications, or both, can be provided by the horn
speakers or the strobe. These indications allow you to
operate the system from outside the premises with
confidence. The installer can program audible and
visual indication beeps by selecting Options 4 and 8
in Location 424 (refer to Section 18.1 System Options 1
on page 78).
Table 19: Horn Speaker Indication Beeps for
No. of Beeps
One
Two
One two-tone beep
Table 20: Strobe Indications for Remote
Strobe Duration
3 sec
6 sec
6 sec
Remote Operations
System Status
System disarmed
System armed in AWAY Mode
System armed in STAY Mode 1
Operations
System Status
System disarmed
System armed in AWAY Mode
System armed in STAY Mode 1