ICP-CC408 | Installation Guide | 6.0
As each zone is selected to be isolated,
the corresponding zone indicator flashes.
If you make a mistake, enter the incorrect
zone number and press [STAY]. This zone
is no longer selected to be isolated and
the zone indicator is extinguished.
This function does not work on a
partitioned ICP-CC408 Control Panel.
4. Press [AWAY].
Two beeps sound and the system returns to the
disarmed state.
The indicators for the zones you selected and the
STAY indicator are extinguished.
Example
If you want to select zones 2, 5, and 6, enter:
[1 2 3 4 4][AWAY][2][STAY][5][STAY][6][STAY]
[AWAY]
You can disable all zones selected to be automatically
isolated for STAY Mode 2 at any time. To disable
STAY Mode 2 zones:
Enter the Installer Code and press [4][AWAY]
[AWAY].
6.1.5

Satellite Siren Service Mode

If the SS914 Satellite Siren (EDMSAT) is connected
to Output 1, this function allows you to perform
service work on the system without activateing the
satellite siren. The satellite siren returns to its normal
working state the next time the system is armed.
To enter Satellite Siren Service Mode:
Enter the Installer Code and press [5][AWAY].
Three beeps sound.
6.1.6
Turning Telephone Monitor Mode On
and Off
Telephone Monitor Mode allows you to use the
remote codepad for visual representation of data
transmissions between the control panel and the base
station receiver. The dialing sequence is also shown
in this mode.
The codepad beeps once every 2 sec when
Telephone Monitor Mode is active, whether the
system is in Installer's Programming Mode or normal
operating mode. The first five indicators show the
progressive steps during a transmission to the base
station receiver.
Bosch Security Systems, Inc. | 12/08 | F01U089463-02
System Functions
Table 28: Telephone Monitor Mode Indications
Zone LED
1
2
3
4
5
None
To turn Telephone Monitor Mode on:
Enter the Installer Code and press [6][AWAY].
Three beeps sound.
To turn Telephone Monitor Mode off:
Enter the Installer Code and press [6][AWAY].
Two beeps sound.
You must exit from Telephone Monitor
Mode to resume normal operations.
6.1.7

Walk Test Mode

Walk Test Mode allows you to test detection devices
to ensure they are functioning correctly. Before
activating Walk Test Mode, isolate any zones that are
not required for testing. Refer to Section 4.11 Isolating
Zones 4.11 Isolating Zones on page 23 for more
information.
To enter Walk Test Mode:
1. Enter the Installer Code and press [7][AWAY].
Three beeps sound and the STAY and AWAY
indicators flash. The codepad beeps once per sec
when Walk Test Mode is active.
2. Unseal and seal the zones to be tested.
The codepad sounds one long beep and the horn
speaker sounds one short beep each time a zone
is sealed or unsealed.
3. Press [AWAY] to exit from this function.
Two beeps sound and the STAY and AWAY
indicators are extinguished. The system returns
to the disarmed state.
6.1.8

Event Memory Recall Mode

This function allows you to play back the last 40
system events that occurred. Event Memory Recall
Mode reports all alarms and each arming or
disarming of the system and helps with
troubleshooting system faults. The events are shown
using the codepad indicators.
To enter Event Memory Recall Mode:
Enter the Installer Code and press [8][AWAY]. Three
beeps sound. The events are played back by the
codepad indicators in reverse chronological order.
Dialing Event
Telephone line seized
Dialing phone number
Handshake received
Data is being transmitted
Kiss-off received
Telephone line released