R911299722 / 02 | Rexroth IndraControl VCP 20
Display and Operating Components
6.2.5
User Mode Switch
S1
S2
S3
S4
S5
I
X
–
–
X
I
X
I
–
X
–
I
–
–
X
–
–
–
I
X
I
–
–
I
X
I
–
I
I
X
Fig. 6-4: User mode switch
The user mode switch is located on the rear of the small operator termi-
nal.
The switch positions for ON or OFF are printed onto the user mode
switch.
S6
S7
S8 Operating Mode
X
X
X
Standard mode with PLC (default upon delivery)
X
X
X
Standard mode without PLC
X
X
X
Transparent mode with start- and stop code of the keys
X
X
X
Transparent mode without stop code of the keys
X
X
X
Activate download (erases the application memory) and
default contrast / brightness setting
X
X
X
Activate upload
Legend for table:
I = Switch ON
– = Switch OFF
X = Any switch position
Electric Drives and Controls | Bosch Rexroth AG
6-7