Example
If the events occurred in the following order:
Table 29: Event Sequence
Sequence
Event
1
System armed in AWAY Mode
2
Alarm in Zone 3
3
Alarm in Zone 4
4
System disarmed
The alarm memory is played back in this order:
Table 30: Event Memory Playback
Sequence
Indication
1
All indicators off
except MAINS
2
Zone 4 and AWAY
indicators light
3
Zone 3 and AWAY
indicators light
4
AWAY indicator
lights
Each event is indicated by a beep and a lit indicator.
Resetting a disarmed 24-Hour Alarm is indicated by
a beep only.
After the last event, three beeps sound to indicate the
end of playback. You can stop the replay at any time
by pressing [AWAY].
If the system is armed in STAY Mode 1 or
STAY Mode 2, the STAY indicator shows
the event memory playback. There is no
differentiation between STAY Mode 1
and STAY Mode 2.
If the control panel is powered down, the
memory of all events will not be lost by
non-volatile memory.
6.2

Master Code Functions

Master Code Functions allow users with the
appropriate priority level to perform certain
supervisory level functions. You can use these
functions only when the system is disarmed.
The default Master Code is 2580 and is
User Code 1. You can program multiple
Master Codes. Refer to Section 13.3
User Code Priority on page 55 for more
information.
To access a Master Code function:
Enter the Master Code and press the corresponding
function digit and the [AWAY] button. The Master
Code functions are listed in Table 31.
Bosch Security Systems, Inc. | 12/08 | F01U089463-02
System Functions
Table 31: Master Code Functions
Function
0
1
2
3
4
5
Event
System disarmed
6
Alarm in Zone 4
7
Alarm in Zone 3
8
System armed in
9
AWAY Mode
6.2.1
This Master Code function operates only with
partitioned ICP-CC408 Systems and allows Master
Codes allocated to both Area 1 and Area 2 to arm or
disarm both areas at the same time.
This feature allows a Master Code holder to arm or
disarm the system by pressing one extra button
rather than entering a code twice. You can use either
the CP5 Area Addressable Codepad (CP500AW) or
the Master Partitioned Codepad (CP500PW) with
this function. To enable this feature, select Option 2
in Location 433 (refer to Section 19.3.2 Partitioning
Options 2 on page 83).
To arm or disarm both areas in AWAY Mode at
the same time:
Enter your Master Code and press [0][AWAY].
Two beeps sound and both areas are armed or
disarmed from AWAY Mode.
To arm or disarm both areas in STAY Mode 1 at
the same time:
Enter your Master Code and press [0][STAY].
Two beeps sound and both areas are armed or
disarmed from STAY Mode 1.
6.2.2
This function allows a Master Code holder to change
or delete a User Code.
Description

Arm or disarm both areas at the same time

(Refer to Section 6.2.1)
Add, change, and delete User
Codes/Remote Radio User Codes
(Sections 6.2.2 and 6.2.3)
Change domestic phone numbers
(Section 6.2.4)
Change Telco Arm/Disarm Sequence
(Section 6.2.5)
Set zones for STAY Mode 2
(Section 6.2.6)
Turn outputs on and off
(Section 6.2.7)
Set the date and time
(Section 6.2.8)
Walk Test Mode
(Section 6.2.9)
Event Memory Recall Mode
(Section 6.2.10)
Reserved
Arm or Disarm Both Areas at the Same
Time

Changing and Deleting User Codes

EN | 33