ICP-CC488 | User's Guide | 3.
Table 8:
Arming Methods

Mode

Arming Method
AWAY Mode
Arms the entire system. Refer to
Section 3.10.2 Arming in AWAY Mode.
STAY Mode 1
Arms all zones except those
programmed to be automatically
isolated by the installer. Refer to
Section 3.10.3 Arming in STAY Mode
1.
STAY Mode 2
Arms all zones except those
programmed to be automatically
isolated by the Master Code holder.
Refer to Section 3.10.4 Arming in
STAY Mode 2.
3.10.1

Forced Arming

The feature of arming the system when a zone is not
sealed is known as forced arming. If the system does
not arm and a long beep is heard, forced arming is
not permitted. If this is the case, you must ensure
that all zones are sealed or manually isolated before
you can arm the system. Refer to Section 8. Isolating
Zones on page 11.
3.10.2

Arming in AWAY Mode

When you leave your premises and require all zones
to be in a ready state to detect intrusion, arm the
system in AWAY Mode.
There are two different methods for arming the
system in AWAY Mode. Method one is standard and
always operates. Method two is optional and can be
disabled by your installer if you do not want to use
single button arming.
Table 9:
How to Arm the System in AWAY
Mode
Method
Enter your user code followed by
the [#] button (for example,
One
[2580#]).
Two beeps sound and the AWAY
indicator displays. Exit Time starts
counting.
Method
Hold down the [#] button until two
Two
beeps sound.
The AWAY indicator displays and
Exit Time starts counting.
3.10.3

Arming in STAY Mode 1

STAY Mode 1 is only used when the perimeter and
unused areas of the premises need to be armed to
detect an intruder from entering the premises. At the
same time, you can move freely within an area that is
automatically isolated.
Only your security company can program zones
automatically isolated in STAY Mode 1.
Bosch Security Systems, Inc. | 12/08 | F01U089456-02
Codepad Indicators
There are two different methods for arming the
system in STAY Mode 1. Method one is standard
and always operates. Method two is optional and
may be disabled by your installer if you do not want
to use single button arming.
Entry Guard Timer for STAY Mode 1
When arming the system in STAY Mode 1, an
optional entry timer called Entry Guard Timer for
STAY Mode 1 is available. Use this entry timer to
delay the sirens if a zone is not automatically isolated
and activated an alarm condition. Entry Guard
Timer For STAY Mode 1 is the delay time used for
all zones except 24-hour zones when the system is
armed in STAY Mode 1 or STAY Mode 2.
If the Entry Guard Timer for STAY Mode 1 is
programmed and a zone was not automatically
isolated is activated, the codepad beeps twice a sec
until the entry timer expires or the system is
disarmed. If the alarm condition is not reset by
entering your user code followed by the [#] button
(such as, [2580#]) before the entry timer expires, the
sirens activate into alarm. Only your installer can
program this feature.
Table 10: How to Arm the System in STAY
Method One
Method Two
3.10.4
STAY Mode 2 is only used when the perimeter and
unused areas of the premise need to be armed to
detect an intruder from entering the premise. At the
same time, allowing you to move freely within an
area that is automatically isolated. Any Master Code
user can program zones to be automatically isolated
in STAY Mode 2.
Mode 1
Enter your user code followed by the [*]
button (for example, [2580*]).
Two beeps sound and the STAY
indicator displays. Exit Time starts
counting.
Any zones programmed to be
automatically isolated in STAY Mode 1
flash until Exit Time expires. At the end of
Exit Time, all zones selected to be
automatically isolated turn off and the
codepad gives one short beep.
Hold down the [*] button until two beeps
sound.
The STAY indicator displays and Exit
Time starts counting.
Any zones programmed to be
automatically isolated in STAY Mode 1
flash until Exit Time expires. At the end of
Exit Time, the zone indicators turn off
and the codepad gives one short beep.

Arming in STAY Mode 2

EN | 8