to re-calibrate; In the correction process by pressing the ESC key,
will exit, holding compensator parameters unchanged.

9.7 Config (Instrument constant)

Operations are permitted only when the instrument was tested
strictly. We recommend you to set it after it is tested by the factory or
professional verification institutions. Notice: the multiplication
constant is zero.
The input operation of additive constant (Add const) is same as
it of multiplication constant (Mul. const).Here, take additive constant
for example.
In the 'Config' menu interface, press [1] to enter the interface of
inputting additive constant, as shown in the picture below:
After inputting, press [Enter] with a prompt "Saved" appearing,
then exit the interface.

9.8 Select code file

In the second page of "Menu",press [3](Select CodeFile) to enter
the interface of "Select CodeFile"

9.9 Gird scale

Formula:
1) Altitude factor= R / (R+Altitude)
R:the earth's average curvature radius
Altitude: Altitude above the mean sea level
2) Scale factor
Scale factor:the measurement station scale factor
3) Grid scale factor of coordinate