276 Chapter 17 Hardware procedures
241-1501-240 5.2S2
7054 0102, indicating an FP port is connected to the wrong sparing
panel port
7054 0103, indicating the sparing panel is not responding
Do whatever remedial action is required to get rid of the alarms.
3
On an NTQS31 sparing panel, press the FP selection button until the
numeral 1 appears in the LED display beside it. The button is the upper
one of the pair.
4
Press the port selection button until the hexadecimal number for one
appears in the LED display beside the button. The button is the lower one
of the pair.
5
Connect the test equipment according to the equipment manufacturer's
instructions.
6
Run the test equipment to verify connectivity according to the equipment
manufacturer's instructions.
7
Record the test result for the FP to sparing panel path.
8
Repeat step 1 to step 7 until you cycle through all of the ports of each FP
connected to the sparing panel and test each one.
9
For each port that failed the transmit connectivity test, check the cable
connectors, cable, and cable connections, then test the FP. Re-test each
as you check. If any port still fails the test, contact your administration to
decide what to replace.