276 Chapter 17 Hardware procedures
241-1501-240 5.2S2
•
7054 0102, indicating an FP port is connected to the wrong sparing
panel port
•
7054 0103, indicating the sparing panel is not responding
Do whatever remedial action is required to get rid of the alarms.
3
On an NTQS31 sparing panel, press the FP selection button until the
numeral 1 appears in the LED display beside it. The button is the upper
one of the pair.
4
Press the port selection button until the hexadecimal number for one
appears in the LED display beside the button. The button is the lower one
of the pair.
5
Connect the test equipment according to the equipment manufacturer's
instructions.
6
Run the test equipment to verify connectivity according to the equipment
manufacturer's instructions.
7
Record the test result for the FP to sparing panel path.
8
Repeat step 1 to step 7 until you cycle through all of the ports of each FP
connected to the sparing panel and test each one.
9
For each port that failed the transmit connectivity test, check the cable
connectors, cable, and cable connections, then test the FP. Re-test each
as you check. If any port still fails the test, contact your administration to
decide what to replace.