Table 76 SNMP System Traps (continued)
OPTION
OBJECT LABEL
voltage
zyHwMonitorPowerSupplyVolt
ageOutOfRange
zyHwMonitorPowerSupplyVolt
ageOutOfRangeRecovered
powersource
zyHwMonitorPowerSourceAbn
ormal
zyHwMonitorPowerSourceAbn
ormalRecovered
zyHwMonitorPowerSourceStat
usChange
reset
zySysMgmtUncontrolledSystem
Reset
zySysMgmtControlledSystemR
eset
zySysMgmtBootImageInconsist
ence
RebootEvent
timesync
zyDateTimeTrapTimeServerNot
Reachable
zyDateTimeTrapTimeServerNot
ReachableRecovered
loopguard
zyLoopGuardLoopDetect
errdisable
zyErrdisableDetect
zyErrdisableRecovery
Chapter 26 SNMP
OBJECT ID
1.3.6.1.4.1.890.1.15
.3.26.2.3
1.3.6.1.4.1.890.1.15
.3.26.2.9
1.3.6.1.4.1.890.1.15
.3.26.2.10
1.3.6.1.4.1.890.1.15
.3.26.2.11
1.3.6.1.4.1.890.1.15
.3.26.2.12
1.3.6.1.4.1.890.1.15
.3.49.2.1
1.3.6.1.4.1.890.1.15
.3.49.2.2
1.3.6.1.4.1.890.1.15
.3.49.2.3
1.3.6.1.4.1.890.1.5.
1.1.2
1.3.6.1.4.1.890.1.15
.3.82.3.1
1.3.6.1.4.1.890.1.15
.3.82.3.2
1.3.6.1.4.1.890.1.15
.3.45.2.1
1.3.6.1.4.1.890.1.15
.3.24.4.1
1.3.6.1.4.1.890.1.15
.3.24.4.2
XS3800-28 User's Guide
193
DESCRIPTION
This trap is sent when the power voltage
goes above or below the normal operating
range.
This trap is sent when the power voltage
recovers to the normal operating range.
This trap is sent when a power supply module
status changes.
This trap is sent when a power supply module
recovers to show normal status.
This trap is sent when the Switch power
source switches from the current in-use
power supply module to another.
This trap is sent when the Switch
automatically resets.
This trap is sent when the Switch resets by an
administrator through a management
interface.
This trap is sent when the index number of
image which is loaded when the Switch
starts up is different from what is specified
through the CLI.
This trap is sent when the Switch reboots by
an administrator through a management
interface.
This trap is sent when the Switch's date and
time is not manually entered or the specified
time server is not reachable.
This trap is sent when the Switch's real time
clock is up to date.
This trap is sent when loopguard shuts down
a port.
This trap is sent when an error is detected on
a port, such as a loop occurs or the rate limit
for specific control packets is exceeded.
This trap is sent when the Switch ceases the
action taken on a port, such as shutting
down the port or discarding packets on the
port, after the specified recovery interval.