3.4.4 Field Identification

In order to properly synchronize to the source data stream and capture the correct fields, field
identification needs to be performed. Field identification is made using one of three methods: EAV, field
indicator input, or field detect logic. The field identification method is determined by the EXC, FLDD, and
FINV bits in VCxCTL.
EXC
0
0
1
1
In the BT.656 standard and in many Y/C standards, a field identification (F) bit is contained in EAV and
SAV codes embedded in the data stream. In the EAV field detect method, the F bit in the EAV of the first
line of every field is checked. If F = 0, then the current field is defined as field 1. If F = 1, then the current
field is defined as field 2. Depending on how the first line of a field is defined (as determined by the VRST
bit in VCxCTL) and the video stream being captured, the F value at the start of a field may not reflect the
actual field being supplied. The FINV bit in VCxCTL allows the detected field value to be inverted. (For
example, in BT.656 525/60 operation, the F bit changes to 0 to indicate field 1 on the fourth line of the
field. If the VRST bit is set so the line counter begins counting at line 1 of the field (the first EAV where V
is 1), then the F bit still indicates field 2 (F = 1) and needs to be inverted. If the VRST bit is set to start
counting lines beginning with the first active line (the first EAV where V is 0), the F value will have already
changed to indicate field 1 (F = 0) and no inversion is necessary.)
56
Video Capture Port
Figure 3-6. HCOUNT Operation Example (EXC = 1)
276
Blanking
843
844
857
0
63
n−1
779
780
793
794
857
n−1
721
722
735
736
799
n−1
1
2
15
16
79
Table 3-9. Field Identification Programming
VCxCTL Bit
FLDD
Field Detect Method
0
EAV code
1
EAV code
0
Use FID input
1
Use field detect (from HSYNC and VSYNC inputs)
Active Video
64
119
120
121
122
123
124
n
0
55
56
57
58
59
60
800
855
856
857
0
1
2
80
135
136
137
138
139
140
n
www.ti.com
1440
840
842
842
843
844
776
777
778
779
780
n
718
719
720
721
722
n
856
857
0
1
2
n+1
SPRUEM1 – May 2007
Submit Documentation Feedback

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tms320dm647

Table of Contents