Oil System
Lubricant
– Preferred Lubricant
–Acceptable Lubricant
Capacity
Cooling System
Thermostat
Maximum Temperature
Water pressure
Electrical System
Minimum Battery Requirements
Alternator
Tachometer Setting
Engine Fuse
Ignition System
Type
Firing Order
Ignition Timing
RPM Limit in Gear
RPM Limit in Neutral
Crankshaft Position Sensor Air Gap
Spark Plug
Gearcase
Gear Ratio
Lubricant
– Capacity
Shift Rod Height
Shift Cable Stroke
Trim & Tilt System
Lubrication
Fluid Capacity
Trim Range
Tilt Range
HP
60 H.O.
Evinrude/Johnson XD100, XD50, XD30; or
NMMA TC-W3 certified
2.4 qt. (2.3 l)
143°F (62°C)
212°F (100°C)
19 to 21 psi @ 5000 RPM
640 CCA (800 MCA) or 800 CCA (1000 MCA) below 32° F (0° C)
25-Amp fully regulated. Refer to Installation and Predelivery Guide for multiple bat-
tery applications.
6 pulse (12 pole)
P/N 967545 – 10 A
Capacitor Discharge
1-2-3
EMM Controlled
6250
1800
Fixed
Refer to Emission Control Information Label
†
Champion
QC10WEP @ 0.028 ± 0.003 in. (0.71 mm)
Refer to Models Covered on p. 11.
Evinrude HPF Pro Lubricant
20 in. (L) Models: 31.6 fl. oz. (935 ml)
25 in. (X) Models: 32.8 fl. oz. (970 ml)
20 in. (L) Models: 21.25 (539.75 mm) ± one-half turn
25 in. (X) Models: 26.25 (666.75 mm) ± one-half turn
1.125 to 1.330 in. (28.6 to 33.8 mm) measured between NEUTRAL and FORWARD
Evinrude/Johnson Biodegradable TNT Fluid, P/N 763439
21 fl. oz. (620 ml)
0° to 15°
16° to 65°
Reference Information
Service Specifications
65
75
90
1
15