L7: Torque Limit - YASKAWA GA800 Maintenance & Troubleshooting

Ac drive for industrial applications, three-phase 200/400 v class: 1 to 150/600 hp, 6-phase/12-pulse 400 v class: 75 to 600 hp
Hide thumbs Also See for GA800:
Table of Contents

Advertisement

No.
Name
(Hex.)
L6-03
Torque Detection Time 1
(04A3)
L6-04
Torque Detection Selection 2
(04A4)
L6-05
Torque Detection Level 2
(04A5)
L6-06
Torque Detection Time 2
(04A6)
L6-07
Torque Detection Filter Time
(04E5)
L6-08
Mechanical Fatigue Detect
Select
(0468)
L6-09
Mech Fatigue Detect Speed
Level
(0469)
L6-10
Mech Fatigue Detect Delay
Time
(046A)
L6-11
Mech Fatigue Hold Off Time
(046B)

L7: Torque Limit

No.
Name
(Hex.)
L7-01
Forward Torque Limit
(04A7)
RUN
L7-02
Reverse Torque Limit
(04A8)
RUN
L7-03
Forward Regenerative Trq
Limit
(04A9)
RUN
YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance & Troubleshooting
V/f
CL-V/f
OLV
CLV
AOLV
Sets the detection time for Overtorque/Undertorque Detection 1.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the speed range that detects overtorque and undertorque and the operation of drives (operation
status) after detection.
0 : Disabled
1 : oL @ Speed Agree - Alarm only
2 : oL @ RUN - Alarm only
3 : oL @ Speed Agree - Fault
4 : oL @ RUN - Fault
5 : UL @ Speed Agree - Alarm only
6 : UL @ RUN - Alarm only
7 : UL @ Speed Agree - Fault
8 : UL @ RUN - Fault
V/f
CL-V/f
OLV
CLV
AOLV
Sets the detection level for Overtorque/Undertorque Detection 2. In V/f control, drive rated output
current = 100% value. In vector control, motor rated torque = 100% value.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the detection time for Overtorque/Undertorque Detection 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time constant for a primary filter to the torque reference or to the output current used to
detect overtorque/undertorque.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the speed where the drive detects mechanical deterioration and how the drive operates (operation
status) after detection.
0 : Disabled
1 : oL5 @ Speed > L6-09 - Alarm
2 : oL5 @ |Speed| > L6-09 - Alarm
3 : oL5 @ Speed > L6-09 - Fault
4 : oL5 @ |Speed| > L6-09 - Fault
5 : UL5 @ Speed < L6-09 - Alarm
6 : UL5 @ |Speed| < L6-09 - Alarm
7 : UL5 @ Speed < L6-09 - Fault
8 : UL5 @ |Speed| < L6-09 - Fault
V/f
CL-V/f
OLV
CLV
AOLV
Sets the speed level where the drive will operate the mechanical deterioration detection function, as a
percentage of the Maximum Output Frequency.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output
frequency.
• A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
• A1-02 = 8: E9-02 [Maximum Speed]
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time for mechanical deterioration detection.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time that the drive will start mechanical deterioration detection triggered by the cumulative
operation time of the drive.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the torque limit value for forward motoring as a percentage, where motor rated torque is the
100% value.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the torque limit value for reversed motoring as a percentage, where motor rated torque is the
100% value.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the torque limit value for forward regenerative conditions as a percentage of the motor rated
torque.
3.11 L: Protection Functions
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default
(Range)
0.1 s
(0.0 - 10.0 s)
0
(0 - 8)
150%
(0 - 300%)
0.1 s
(0.0 - 10.0 s)
0 ms
(0 - 1000 ms)
0
(0 - 8)
110.0%
(-110.0 - 110.0%)
0.1 s
(0.0 - 10.0 s)
0 h
(0 - 65535 h)
Default
(Range)
3
200%
(0 - 300%)
200%
(0 - 300%)
200%
(0 - 300%)
231