C4: Torque Compensation - YASKAWA GA800 Maintenance & Troubleshooting

Ac drive for industrial applications, three-phase 200/400 v class: 1 to 150/600 hp, 6-phase/12-pulse 400 v class: 75 to 600 hp
Hide thumbs Also See for GA800:
Table of Contents

Advertisement

No.
Name
(Hex.)
C3-24
Motor 2 Slip Comp during
Regen
(0243)
C3-28
Adaptive Slip Control Mode
(1B5B)
Expert

C4: Torque Compensation

No.
Name
(Hex.)
C4-01
Torque Compensation Gain
(0215)
RUN
C4-02
Torque Compensation Delay
Time
(0216)
RUN
C4-03
Torque Compensation @
FWD Start
(0217)
C4-04
Torque Compensation @
REV Start
(0218)
C4-05
Torque Compensation Time
(0219)
C4-06
Motor 2 Torque Comp Delay
Time
(021A)
C4-07
Motor 2 Torque
Compensation Gain
(0341)
RUN
C4-19
Torque Ripple Suppress Min
Freq
(0B8D)
Expert
C4-20
Voltage Compensation
Adjust 1
(0BCB)
Expert
C4-21
Voltage Compensation
Adjust 2
(0BCC)
Expert
C4-23
Current Control Gain
(1583)
Expert
YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance & Troubleshooting
V/f
CL-V/f
OLV
CLV
AOLV
Sets the slip compensation during regenerative operation function for motor 2.
0 : Disabled
1 : Enabled Above 6Hz
2 : Enabled Above C3-15
V/f
CL-V/f
OLV
CLV
AOLV
Sets the slip compensation function mode.
0 : Normal
1 : Advanced
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain for the torque compensation function. Use this parameter value for motor 1 when
operating multiple motors.
Note:
If A1-02 = 8 [Control Method Selection = EZOLV], you cannot change the setting while the
drive is running.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the torque compensation delay time. Usually it is not necessary to change this setting.
Note:
• When A1-02 = 5 [Control Method Selection = OLV/PM], you cannot change the setting while
the drive is running.
• When A1-02 = 8 [EZOLV], you cannot change the setting while the drive is running.
V/f
CL-V/f
OLV
CLV
AOLV
Set the amount of torque reference for forward start as a percentage of the motor rated torque.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the amount of torque reference for reverse start as a percentage of the motor rated torque.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the starting torque constant to use with C4-03 and C4-04 [Torque Compensation @ FWD/REV
Start].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the value if ov [Overvoltage] occurs with sudden changes in the load, at the end of acceleration,
or at the start of deceleration.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain for motor 2 torque compensation function when using the Motor Switch function.
V/f
CL-V/f
OLV
CLV
AOLV
If there is slow oscillation at low speeds, adjust this setting. Usually it is not necessary to change this
setting.
Increase this parameter in 1.0 Hz increments when current ripples and torque ripples occur during
low-speed operation. Set this parameter to 0.0 to disable the function if increasing the value does not
fix the problem.
Note:
Set C4-20 [Voltage Compensation Adjust 1] ≠ 0 to enable this parameter.
V/f
CL-V/f
OLV
CLV
AOLV
Sets voltage precision compensation. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets voltage precision compensation. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Current control gain. Usually it is not necessary to change this parameter.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
3.6 C: Tuning
Default
(Range)
0
(0 - 2)
0
(0, 1)
Default
(Range)
Determined by A1-02
(0.00 - 2.50)
Determined by A1-02
(0 - 60000 ms)
0.0%
(0.0 - 200.0%)
0.0%
(-200.0 - 0.0%)
10 ms
(0 - 200 ms)
150 ms
(0 - 10000 ms)
1.00
(0.00 - 2.50)
0.1 Hz
(0.0 - 10.0 Hz)
120 Hz
(0 - 200 Hz)
5
3
(0 - 10)
1.00
(0.50 - 2.50)
169