H7: Virtual Mfio Selection - YASKAWA GA800 Maintenance & Troubleshooting

Ac drive for industrial applications, three-phase 200/400 v class: 1 to 150/600 hp, 6-phase/12-pulse 400 v class: 75 to 600 hp
Hide thumbs Also See for GA800:
Table of Contents

Advertisement

No.
Name
(Hex.)
H6-03
Terminal RP Function Gain
(042E)
RUN
H6-04
Terminal RP Function Bias
(042F)
RUN
H6-05
Terminal RP Filter Time
(0430)
RUN
H6-06
Terminal MP Monitor
Selection
(0431)
RUN
H6-07
Terminal MP Frequency
Scaling
(0432)
RUN
H6-08
Terminal RP Minimum
Frequency
(043F)
H6-09
Voltage Phase Sync MP
Selection
(156E)

H7: Virtual MFIO selection

No.
Name
(Hex.)
H7-00
Virtual MFIO selection
(116F)
Expert
H7-01
Virtual Multi-Function Input
1
(1185)
Expert
H7-02
Virtual Multi-Function Input
2
(1186)
Expert
H7-03
Virtual Multi-Function Input
3
(1187)
Expert
H7-04
Virtual Multi-Function Input
4
(1188)
Expert
H7-10
Virtual Multi-Function
Output 1
(11A4)
Expert
H7-11
Virtual Output 1 Delay Time
(11A5)
Expert
H7-12
Virtual Multi-Function
Output 2
(11A6)
Expert
YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance & Troubleshooting
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain used when the function in H6-01 [Terminal RP Pulse Train Function] is input to
terminal RP.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the bias used when the function in H6-01 [Terminal RP Pulse Train Function] is input to
terminal RP. Sets a value at the time when the pulse train is 0 Hz.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time constant for the pulse train input primary delay filters.
V/f
CL-V/f
OLV
CLV
AOLV
Sets a function for pulse train monitor output terminal MP. Sets the "x-xx" part of the Ux-xx monitor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency of the pulse train output signal used when the monitor set with H6-06 [Terminal
MP Monitor Selection] is 100%.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the minimum frequency of the pulse train signal that terminal RP can detect.
V/f
CL-V/f
OLV
CLV
AOLV
Set whether to output the pulse synchronized with drive output voltage phase from the pulse train
monitor output terminal MP. This parameter is only enabled when H6-06 = 102 [Terminal MP
Monitor Selection = Output Frequency] and H6-07 = 0 [Terminal MP Frequency Scaling = 0 Hz].
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to enable and disable the virtual I/O function. Set this parameter to 1 to operate the
virtual I/O function.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that enters the virtual input set in H7-10 [Virtual Multi-Function Output 1].
Note:
1B [Programming Lockout] and 11B [Inverse Input of 1B] are not available.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that enters the virtual input set in H7-12 [Virtual Multi-Function Output 2].
Note:
1B [Programming Lockout] and 11B [Inverse Input of 1B] are not available.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that enters the virtual input set in H7-14 [Virtual Multi-Function Output 3].
Note:
1B [Programming Lockout] and 11B [Inverse Input of 1B] are not available.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that enters the virtual input set in H7-16 [Virtual Multi-Function Output 4].
Note:
1B [Programming Lockout] and 11B [Inverse Input of 1B] are not available.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for virtual digital output 1.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the minimum ON time for virtual digital output 1.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for virtual digital output 2.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
3.10 H: Terminal Functions
Default
(Range)
100.0%
(0.0 - 1000.0%)
0.0%
(-100.0 - 100.0%)
0.10 s
(0.00 - 2.00 s)
102
(000, 031, 101, 102, 105,
116, 501, 502, 801 - 809,
821 - 825, 831 - 839, 851 -
855)
1440 Hz
(0 - 32000 Hz)
0.5 Hz
(0.1 - 1000.0 Hz)
0
(0, 1)
Default
(Range)
0
(0, 1)
F
(1 - 19F)
F
(1 - 19F)
F
(1 - 19F)
F
(1 - 19F)
F
(0 - 1A7)
0.1 s
(0.0 - 25.0 s)
F
(0 - 1A7)
3