F6: Communication Options - YASKAWA GA800 Maintenance & Troubleshooting

Ac drive for industrial applications, three-phase 200/400 v class: 1 to 150/600 hp, 6-phase/12-pulse 400 v class: 75 to 600 hp
Hide thumbs Also See for GA800:
Table of Contents

Advertisement

3.9 F: Options
No.
Name
(Hex.)
F5-03
Terminal P3-PC Function
Select
(039B)
F5-04
Terminal P4-PC Function
Select
(039C)
F5-05
Terminal P5-PC Function
Select
(039D)
F5-06
Terminal P6-PC Function
Select
(039E)
F5-07
Terminal M1-M2 Function
Select
(039F)
F5-08
Terminal M3-M4 Function
Select
(03A0)
F5-09
DO-A3 Output Mode
Selection
(03A1)

F6: Communication Options

No.
Name
(Hex.)
F6-01
Communication Error
Selection
(03A2)
F6-02
Comm External Fault (EF0)
Detect
(03A3)
F6-03
Comm External Fault (EF0)
Select
(03A4)
F6-04
bUS Error Detection Time
(03A5)
F6-06
Torque Reference/Limit by
Comm
(03A7)
188
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function of terminal P3-PC on the DO-A3 option. Set F5-09 = 2 [DO-A3 Output Mode
Selection = Programmable (F5-01 to F5-08)] to enable this function.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function of terminal P4-PC on the DO-A3 option. Set F5-09 = 2 [DO-A3 Output Mode
Selection = Programmable (F5-01 to F5-08)] to enable this function.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function of terminal P5-PC on the DO-A3 option. Set F5-09 = 2 [DO-A3 Output Mode
Selection = Programmable (F5-01 to F5-08)] to enable this function.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function of terminal P6-PC on the DO-A3 option. Set F5-09 = 2 [DO-A3 Output Mode
Selection = Programmable (F5-01 to F5-08)] to enable this function.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function of terminal M3-M2 on the DO-A3 option. Set F5-09 = 2 [DO-A3 Output Mode
Selection = Programmable (F5-01 to F5-08)] to enable this function.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function of terminal M3-M4 on the DO-A3 option. Set F5-09 = 2 [DO-A3 Output Mode
Selection = Programmable (F5-01 to F5-08)] to enable this function.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the output mode of signals from the DO-A3 option.
0 : Predefined Individual Outputs
1 : Binary Output
2 : Programmable (F5-01 to F5-08)
V/f
CL-V/f
OLV
CLV
AOLV
Sets the method to stop the motor or let the motor continue operating when the drive detects bUS
[Option Communication Error].
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast Stop (Use C1-09)
3 : Alarm Only
4 : Alarm (Run at d1-04)
5 : Alarm - Ramp Stop
V/f
CL-V/f
OLV
CLV
AOLV
Sets the conditions at which EF0 [Option Card External Fault] is detected.
0 : Always Detected
1 : Detected during RUN Only
V/f
CL-V/f
OLV
CLV
AOLV
Sets the method to stop the motor or let the motor continue operating when the drive detects an EF0
[Option Card External Fault].
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast Stop (Use C1-09)
3 : Alarm Only
V/f
CL-V/f
OLV
CLV
AOLV
Sets the delay time for the drive to detect bUS [Option Communication Error].
Note:
When you install an option card in the drive, the parameter value changes to 0.0 s.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that enables and disables the torque reference and torque limit received from the
communication option.
0 : Disabled
1 : Enabled
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance & Troubleshooting
Default
(Range)
2
(0 - 1A7)
4
(0 - 1A7)
6
(0 - 1A7)
37
(0 - 1A7)
F
(0 - 1A7)
F
(0 - 1A7)
0
(0 - 2)
Default
(Range)
1
(0 - 5)
0
(0, 1)
1
(0 - 3)
2.0 s
(0.0 - 5.0 s)
0
(0, 1)