3.16 T: Motor Tuning

3.16

T: Motor Tuning

T0: Tuning Mode Selection

No.
Name
(Hex.)
T0-00
Tuning Mode Selection
(1197)

T1: Induction Motor Auto-Tuning

No.
Name
(Hex.)
T1-00
Motor 1/Motor 2 Selection
(0700)
T1-01
Auto-Tuning Mode Selection
(0701)
T1-02
Motor Rated Power
(0702)
T1-03
Motor Rated Voltage
(0703)
T1-04
Motor Rated Current
(0704)
T1-05
Motor Base Frequency
(0705)
T1-06
Number of Motor Poles
(0706)
T1-07
Motor Base Speed
(0707)
T1-08
Encoder Pulse Count (PPR)
(0708)
T1-09
Motor No-Load Current
(0709)
T1-10
Motor Rated Slip Frequency
(070A)
T1-11
Motor Iron Loss
(070B)
252
V/f
CL-V/f
OLV
CLV
AOLV
Sets the type of Auto-Tuning.
0 : Motor Parameter Tuning
1 : Control Tuning
V/f
CL-V/f
OLV
CLV
AOLV
Sets which motor to tune when motor 1/2 switching is enabled.
You can only use the keypad to set this parameter. You cannot use external input terminals to set it.
Note:
This parameter is enabled when H1-xx = 16 [Motor 2 Selection] is set. When H1-xx ≠ 16 the
keypad will not show this parameter.
1 : Motor 1 (sets E1-xx, E2-xx)
2 : Motor 2 (sets E3-xx, E4-xx)
V/f
CL-V/f
OLV
CLV
AOLV
Sets the type of Auto-Tuning.
0 : Rotational Auto-Tuning
1 : Stationary Auto-Tuning 1
2 : Stationary Line-Line Resistance
V/f
CL-V/f
OLV
CLV
AOLV
Uses the units set in o1-58 [Motor Power Unit Selection] to set the motor rated output power.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the rated voltage (V) of the motor. Enter the base speed voltage for constant output motors.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the rated current (A) of the motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the base frequency (Hz) of the motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of motor poles.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor base speed for Auto-Tuning (min
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of PG (pulse generator, encoder) pulses.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the no-load current of the motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets motor rated slip.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the iron loss for calculating the energy-saving coefficient.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
-1
(r/min)).
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance & Troubleshooting
Default
(Range)
0
(0, 1)
Default
(Range)
1
(1, 2)
Determined by A1-02
(Determined by A1-02)
Determined by o2-04, C6-01
(0.00 - 650.00 HP)
Determined by o2-04, C6-01
(200 V Class: 0.0 - 255.5 V,
400 V Class: 0.0 - 511.0 V)
Determined by o2-04
(10% to 200% of the drive
rated current)
60.0 Hz
(0.0 - 590.0 Hz)
4
(2 to 120)
-1
1750 min
(r/min)
(0 - 35400 min
-1
(r/min))
1024 ppr
(0 - 60,000 ppr)
-
(0 A - T1-04; max. of
2999.9)
-
(0.000 - 20.000 Hz)
Determined by E2-11 or E4-
11
(0 - 65535 W)

Hide quick links: