d3: Jump Frequency

No.
Name
(Hex.)
d3-01
Jump Frequency 1
(0294)
d3-02
Jump Frequency 2
(0295)
d3-03
Jump Frequency 3
(0296)
d3-04
Jump Frequency Width
(0297)
d4: Frequency Ref Up/Down & Hold
No.
Name
(Hex.)
d4-01
Freq Reference Hold
Selection
(0298)
d4-03
Up/Down 2 Bias Step
Frequency
(02AA)
RUN
d4-04
Up/Down 2 Ramp Selection
(02AB)
RUN
d4-05
Up/Down 2 Bias Mode
Selection
(02AC)
RUN
d4-06
Frequency Ref Bias (Up/
Down 2)
(02AD)
d4-07
Analog Freq Ref Fluctuate
Limit
(02AE)
RUN
d4-08
Up/Down 2 Bias Upper
Limit
(02AF)
RUN
YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance & Troubleshooting
V/f
CL-V/f
OLV
CLV
AOLV
Sets the median value of the frequency band that the drive will avoid.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the median value of the frequency band that the drive will avoid.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the median value of the frequency band that the drive will avoid.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the width of the frequency band that the drive will avoid.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that saves the frequency reference or the frequency bias (Up/Down 2) after a Stop
command or when de-energizing the drive.
Set H1-xx [MFDI Function Selection] to one of these values to enable this parameter:
• A [Accel/Decel Ramp Hold]
• 10/11 [Up/Down Command]
• 75/76 [Up/Down 2 Command]
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the bias that the Up/Down 2 function adds to or subtracts from the frequency reference.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the acceleration and deceleration times for the Up/Down 2 function to apply the bias to the
frequency reference.
0 : Use Selected Accel/Decel Time
1 : Use Accel/Decel Time 4
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that saves the bias value to the drive when you open or close the two Up/Down 2
Commands [H1-xx = 75, 76]. Set d4-03 [Up/Down 2 Bias Step Frequency] = 0.00 before you set this
parameter.
0 : Hold when Neither Up/Down Closed
1 : Reset when Neither / Both Closed
V/f
CL-V/f
OLV
CLV
AOLV
Saves the bias value from the Up/Down 2 Command where the Maximum Output Frequency is
100%.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output
frequency.
• A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
• A1-02 = 8: E9-02 [Maximum Speed]
V/f
CL-V/f
OLV
CLV
AOLV
If the frequency reference changes for more than the level set to this parameter, then the bias value
will be held. The value is set as a percentage of the Maximum Output Frequency.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output
frequency.
• A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
• A1-02 = 8: E9-02 [Maximum Speed]
V/f
CL-V/f
OLV
CLV
AOLV
Sets the upper limit of the Up/Down 2 bias as a percentage of the Maximum Output Frequency.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the maximum output
frequency.
• A1-02 ≠ 8 [EZOLV]: E1-04 [Maximum Output Frequency]
• A1-02 = 8: E9-02 [Maximum Speed]
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
3.7 d: Reference Settings
Default
(Range)
0.0 Hz
(Determined by A1-02)
0.0 Hz
(Determined by A1-02)
0.0 Hz
(Determined by A1-02)
1.0 Hz
(Determined by A1-02)
Default
(Range)
0
(0, 1)
0.00 Hz
(0.00 - 99.99 Hz)
0
(0, 1)
0
(0, 1)
0.0%
(-99.9 - +100.0%)
1.0%
(0.1 - 100.0%)
100.0%
(0.0 - 100.0%)