O5: Log Function - YASKAWA GA800 Maintenance & Troubleshooting

Ac drive for industrial applications, three-phase 200/400 v class: 1 to 150/600 hp, 6-phase/12-pulse 400 v class: 75 to 600 hp
Hide thumbs Also See for GA800:
Table of Contents

Advertisement

3.13 o: Keypad-Related Settings
No.
Name
(Hex.)
o4-22
Time Format
(154F)
RUN
o4-23
Date Format
(1550)
RUN
o4-24
bAT Detection Selection
(310F)
RUN

o5: Log Function

No.
Name
(Hex.)
o5-01
Log Start/Stop Selection
(1551)
RUN
o5-02
Log Sampling Interval
(1552)
RUN
o5-03
Log Monitor Data 1
(1553)
RUN
o5-04
Log Monitor Data 2
(1554)
RUN
o5-05
Log Monitor Data 3
(1555)
RUN
o5-06
Log Monitor Data 4
(1556)
RUN
o5-07
Log Monitor Data 5
(1557)
RUN
o5-08
Log Monitor Data 6
(1558)
RUN
o5-09
Log Monitor Data 7
(1559)
RUN
o5-10
Log Monitor Data 8
(155A)
RUN
248
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time display format. This parameter is only available when using an LCD keypad.
0 : 24 Hour Clock
1 : 12 Hour Clock
2 : 12 Hour JP Clock
V/f
CL-V/f
OLV
CLV
AOLV
Sets the date display format. This parameter is only available when using an LCD keypad.
0 : YYYY/MM/DD
1 : DD/MM/YYYY
2 : MM/DD/YYYY
V/f
CL-V/f
OLV
CLV
AOLV
Sets operation when the drive detects bAT [Keypad Battery Low Voltage] and TiM [Keypad Time Not
Set].
0 : Disable
1 : Enable (Alarm Detected)
2 : Enable (Fault Detected)
V/f
CL-V/f
OLV
CLV
AOLV
Sets the data log function. This parameter is only available when using an LCD keypad.
0 : OFF
1 : ON
V/f
CL-V/f
OLV
CLV
AOLV
Sets the data log sampling cycle. This parameter is only available when using an LCD keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the data log monitor. This parameter is only available when using an LCD keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the data log monitor. This parameter is only available when using an LCD keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the data log monitor. This parameter is only available when using an LCD keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the data log monitor. This parameter is only available when using an LCD keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the data log monitor. This parameter is only available when using an LCD keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the data log monitor. This parameter is only available when using an LCD keypad.
Note:
When A1-02 = 0 or 5 [Control Method Selection = V/f, OLV/PM], the default setting is 0.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the data log monitor. This parameter is only available when using an LCD keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the data log monitor. This parameter is only available when using an LCD keypad.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance & Troubleshooting
Default
(Range)
1
(0 - 2)
2
(0 - 2)
0
(0 - 2)
Default
(Range)
0
(0 - 1)
100 ms
(100 - 60000 ms)
101
(000, 101 - 999)
102
(000, 101 - 999)
103
(000, 101 - 999)
107
(000, 101 - 999)
108
(000, 101 - 999)
105
(000, 101 - 999)
110
(000, 101 - 999)
112
(000, 101 - 999)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents