F3: Digital Input Option - YASKAWA GA800 Maintenance & Troubleshooting

Ac drive for industrial applications, three-phase 200/400 v class: 1 to 150/600 hp, 6-phase/12-pulse 400 v class: 75 to 600 hp
Hide thumbs Also See for GA800:
Table of Contents

Advertisement

3.9 F: Options

F3: Digital Input Option

No.
Name
(Hex.)
F3-01
Digital Input Function
Selection
(0390)
F3-03
Digital Input Data Length
Select
(03B9)
F3-10
Terminal D0 Function
Selection
(0BE3)
Expert
F3-11
Terminal D1 Function
Selection
(0BE4)
Expert
F3-12
Terminal D2 Function
Selection
(0BE5)
Expert
F3-13
Terminal D3 Function
Selection
(0BE6)
Expert
F3-14
Terminal D4 Function
Selection
(0BE7)
Expert
F3-15
Terminal D5 Function
Selection
(0BE8)
Expert
F3-16
Terminal D6 Function
Selection
(0BE9)
Expert
F3-17
Terminal D7 Function
Selection
(0BEA)
Expert
F3-18
Terminal D8 Function
Selection
(0BEB)
Expert
F3-19
Terminal D9 Function
Selection
(0BEC)
Expert
F3-20
Terminal DA Function
Selection
(0BED)
Expert
F3-21
Terminal DB Function
Selection
(0BEE)
Expert
186
V/f
CL-V/f
OLV
CLV
AOLV
Sets the data format of digital input signals. This parameter is enabled when o1-03 = 0 or 1
[Frequency Display Unit Selection = 0.01 Hz or 0.01% (100% = E1-04)].
Note:
When o1-03 = 2 or 3 [Revolutions Per Minute (RPM) or User Units (o1-10 & o1-11)], the input
signal will be BCD. The o1-03 value sets the setting units.
0 : BCD, 1% units
1 : BCD, 0.1% units
2 : BCD, 0.01% units
3 : BCD, 1 Hz units
4 : BCD, 0.1 Hz units
5 : BCD, 0.01 Hz units
6 : BCD (5-digit), 0.02 Hz
7 : Binary input
8 : Multi-Function Digital Input
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of bits to set the frequency reference with DI-A3.
0 : 8-bit
1 : 12-bit
2 : 16-bit
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for terminal D0 of the DI-A3 option when F3-01 = 8 [Digital Input Function
Selection = Multi-Function Digital Input].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for terminal D1 of the DI-A3 option when F3-01 = 8 [Digital Input Function
Selection = Multi-Function Digital Input].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for terminal D2 of the DI-A3 option when F3-01 = 8 [Digital Input Function
Selection = Multi-Function Digital Input].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for terminal D3 of the DI-A3 option when F3-01 = 8 [Digital Input Function
Selection = Multi-Function Digital Input].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for terminal D4 of the DI-A3 option when F3-01 = 8 [Digital Input Function
Selection = Multi-Function Digital Input].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for terminal D5 of the DI-A3 option when F3-01 = 8 [Digital Input Function
Selection = Multi-Function Digital Input].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for terminal D6 of the DI-A3 option when F3-01 = 8 [Digital Input Function
Selection = Multi-Function Digital Input].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for terminal D7 of the DI-A3 option when F3-01 = 8 [Digital Input Function
Selection = Multi-Function Digital Input].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for terminal D8 of the DI-A3 option when F3-01 = 8 [Digital Input Function
Selection = Multi-Function Digital Input].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for terminal D9 of the DI-A3 option when F3-01 = 8 [Digital Input Function
Selection = Multi-Function Digital Input].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for terminal DA of the DI-A3 option when F3-01 = 8 [Digital Input Function
Selection = Multi-Function Digital Input].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for terminal DB of the DI-A3 option when F3-01 = 8 [Digital Input Function
Selection = Multi-Function Digital Input].
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance & Troubleshooting
Default
(Range)
8
(0 - 8)
2
(0 - 2)
F
(1 - 19F)
F
(1 - 19F)
F
(1 - 19F)
F
(1 - 19F)
F
(1 - 19F)
F
(1 - 19F)
F
(1 - 19F)
F
(1 - 19F)
F
(1 - 19F)
F
(1 - 19F)
F
(1 - 19F)
F
(1 - 19F)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents