L9: Drive Protection 2 - YASKAWA GA800 Maintenance & Troubleshooting

Ac drive for industrial applications, three-phase 200/400 v class: 1 to 150/600 hp, 6-phase/12-pulse 400 v class: 75 to 600 hp
Hide thumbs Also See for GA800:
Table of Contents

Advertisement

3.11 L: Protection Functions
No.
Name
(Hex.)
L8-40
Carrier Freq Reduction Off-
Delay
(04F1)
L8-41
High Current Alarm
Selection
(04F2)
L8-51
STPo I Detection Level
(0471)
Expert
L8-52
STPo Integration Level
(0472)
Expert
L8-53
STPo Integration Time
(0473)
Expert
L8-54
STPo Id Diff Detection
(0474)
Expert
L8-55
Internal DB
TransistorProtection
(045F)
L8-56
Stall P @ Accel Activation
Time
(047D)
Expert
L8-57
Stall Prevention Retry
Counts
(047E)
Expert
L8-90
STPo Detection Level (Low
Speed)
(0175)
Expert
L8-93
Low Speed Pull-out
DetectionTime
(073C)
Expert
L8-94
Low Speed Pull-out Detect
Level
(073D)
Expert
L8-95
Low Speed Pull-out Amount
(077F)
Expert

L9: Drive Protection 2

No.
Name
(Hex.)
L9-16
FAn1 Detect Time
(11DC)
Expert
234
V/f
CL-V/f
OLV
CLV
AOLV
Sets the length of time until the automatically reduced carrier frequency returns to the condition
before the reduction.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to cause an HCA [Current Alarm] when the output current is more than 150% of the
drive rated current.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the STPo [Motor Step-Out Detected] detection level as a percentage of the motor rated current.
Note:
Parameter A1-02 [Control Method Selection] selects which parameter is the motor rated current.
• A1-02 = 5 [OLV/PM]: E5-03 [PM Motor Rated Current (FLA)]
• A1-02 = 8 [EZOLV]: E9-06 [Motor Rated Current (FLA)]
V/f
CL-V/f
OLV
CLV
AOLV
Sets the detection level for STPo [Motor Step-Out Detected] related to the ACR integral value.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the length of time until the drive detects STPo after it is more than the value of L8-51 [STPo I
Detection Level].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the Id deviation detection function for STPo [Motor Step-Out Detected].
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the protection function for the internal braking transistor.
0 : Disable
1 : Protection Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the length time that the acceleration stall prevention function can continue to operate before the
drive detects an STPo [Motor Step-Out Detected].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of times the acceleration stall prevention function can operate until speeds agree
before the drive detects an STPo [Motor Step-Out Detected].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the detection level that the control fault must be equal to or more than to cause an STPo [Motor
Step-Out Detected].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the length of time the drive will wait to start baseblock after detecting LSo [Low Speed Motor
Step-Out].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the detection level for LSo [Low Speed Motor Step-Out] as a percentage of E1-04 [Maximum
Output Frequency].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the average count of LSo [Low Speed Motor Step-Out] detections.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the detection time for FAn1 [Drive Cooling Fan Fault]. Yaskawa recommends that you do not
change this parameter value.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance & Troubleshooting
Default
(Range)
Determined by A1-02
(0.00 - 2.00 s)
0
(0, 1)
0.0%
(0.0 - 300.0%)
1.0
(0.1 - 2.0)
1.0 s
(1.0 - 10.0 s)
1
(0, 1)
1
(0, 1)
5000 ms
(100 - 5000 ms)
10
(1 - 10 times)
Determined by A1-02
(0 - 5000 times)
1.0 s
(0.0 - 10.0 s)
3%
(0 - 10%)
10
(1 - 50 times)
Default
(Range)
4.0 s
(0.0 - 30.0 s)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents