C3: Slip Compensation - YASKAWA GA800 Maintenance & Troubleshooting

Ac drive for industrial applications, three-phase 200/400 v class: 1 to 150/600 hp, 6-phase/12-pulse 400 v class: 75 to 600 hp
Hide thumbs Also See for GA800:
Table of Contents

Advertisement

3.6 C: Tuning
No.
Name
(Hex.)
C2-03
S-Curve Time @ Start of
Decel
(020D)
C2-04
S-Curve Time @ End of
Decel
(020E)

C3: Slip Compensation

No.
Name
(Hex.)
C3-01
Slip Compensation Gain
(020F)
RUN
C3-02
Slip Compensation Delay
Time
(0210)
RUN
C3-03
Slip Compensation Limit
(0211)
C3-04
Slip Compensation at Regen
(0212)
C3-05
Output Voltage Limit
Selection
(0213)
C3-16
Vout Modulation Limit Start
Lvl
(0261)
Expert
C3-17
Vout Modulation Limit Max
Level
(0262)
Expert
C3-18
Output Voltage Limit Level
(0263)
Expert
C3-21
Motor 2 Slip Compensation
Gain
(033E)
RUN
C3-22
Motor 2 Slip Comp Delay
Time
(0241)
RUN
C3-23
Motor 2 Slip Compensation
Limit
(0242)
168
V/f
CL-V/f
OLV
CLV
AOLV
Sets the S-curve deceleration time at start.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the S-curve deceleration time at completion.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain for the slip compensation function. Usually it is not necessary to change this setting.
Note:
• When A1-02 = 4 [AOLV], you cannot change the setting while the drive is running.
• Correctly set these parameters before you change the slip compensation gain:
–E2-01 [Motor Rated Current (FLA)]
–E2-02 [Motor Rated Slip]
–E2-03 [Motor No-Load Current]
V/f
CL-V/f
OLV
CLV
AOLV
Sets the slip compensation delay time when speed is unstable or when the slip compensation
response is too slow. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the upper limit for the slip compensation function as a percentage of the motor rated slip.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the slip compensation function during regenerative operation.
0 : Disabled
1 : Enabled Above 6Hz
2 : Enabled Above C3-15
V/f
CL-V/f
OLV
CLV
AOLV
Sets the automatic reduction of motor magnetic flux when the output voltage is saturated.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the modulation factor that starts the output voltage limit operation when C3-05 = 1 [Output
Voltage Limit Selection = Enabled].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the modulation factor used with C3-18 [Output Voltage Limit Level] for the output voltage limit
operation when C3-05 = 1 [Output Voltage Limit Selection = Enabled].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the maximum drop width of the voltage reference when C3-05 = 1 [Output Voltage Limit
Selection = Enabled].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain for the motor 2 slip compensation function. Usually it is not necessary to change this
setting.
Note:
Correctly set these parameters before changing the slip compensation gain:
• E4-01 [Motor 2 Rated Current]
• E4-02 [Motor 2 Rated Slip]
• E4-03 [Motor 2 Rated No-Load Current]
V/f
CL-V/f
OLV
CLV
AOLV
Sets the slip compensation delay time for motor 2 when speed is unstable or when the slip
compensation response is too slow. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the upper limit for the slip compensation function as a percentage of the motor 2 rated slip.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance & Troubleshooting
Default
(Range)
0.20 s
(0.00 - 10.00 s)
0.00 s
(0.00 - 10.00 s)
Default
(Range)
Determined by A1-02
(0.0 - 2.5)
Determined by A1-02
(0 - 10000 ms)
200%
(0 - 250%)
0
(0 - 2)
0
(0, 1)
90.0%
(70.0 - 90.0%)
100.0%
(85.0 - 100.0%)
90.0%
(50.0 - 100.0%)
Determined by E3-01
(0.0 - 2.5)
Determined by E3-01
(0 - 10000 ms)
200%
(0 - 250%)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents