3.8 E: Motor Parameters
No.
Name
(Hex.)
E3-05
Motor 2 Maximum Output
Voltage
(031B)
E3-06
Motor 2 Base Frequency
(031C)
E3-07
Motor 2 Mid Point A
Frequency
(031D)
E3-08
Motor 2 Mid Point A Voltage
(031E)
E3-09
Motor 2 Minimum Output
Frequency
(031F)
E3-10
Motor 2 Minimum Output
Voltage
(0320)
E3-11
Motor 2 Mid Point B
Frequency
(0345)
Expert
E3-12
Motor 2 Mid Point B Voltage
(0346)
Expert
E3-13
Motor 2 Base Voltage
(0347)
Expert

E4: Motor 2 Parameters

No.
Name
(Hex.)
E4-01
Motor 2 Rated Current
(0321)
E4-02
Motor 2 Rated Slip
(0322)
E4-03
Motor 2 Rated No-Load
Current
(0323)
E4-04
Motor 2 Motor Poles
(0324)
E4-05
Motor 2 Line-to-Line
Resistance
(0325)
E4-06
Motor 2 Leakage Inductance
(0326)
E4-07
Motor 2 Saturation
Coefficient 1
(0343)
E4-08
Motor 2 Saturation
Coefficient 2
(0344)
E4-09
Motor 2 Mechanical Loss
(033F)
Expert
E4-10
Motor 2 Iron Loss
(0340)
E4-11
Motor 2 Rated Power
(0327)
180
V/f
CL-V/f
OLV
CLV
AOLV
Sets the maximum output voltage for the motor 2 V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the base frequency for the motor 2 V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets a middle output frequency for the motor 2 V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets a middle output voltage for the motor 2 V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the minimum output frequency for the motor 2 V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the minimum output voltage for the motor 2 V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets a middle output frequency for the motor 2 V/f pattern. Set this parameter to adjust the V/f
pattern for the constant output range. Usually it is not necessary to change this parameter.
V/f
CL-V/f
OLV
CLV
AOLV
Sets a middle output voltage for the motor 2 V/f pattern. Set this parameter to adjust the V/f pattern
for the constant output range. Usually it is not necessary to change this parameter.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the base voltage for the motor 2 V/f pattern. Set this parameter to adjust the V/f pattern for the
constant output range. Usually it is not necessary to change this parameter.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor rated current for motor 2 in amps.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor rated slip for motor 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the no-load current for motor 2 in amps when operating at the rated frequency and the no-load
voltage.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of poles for motor 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the line-to-line resistance for the motor 2 stator windings.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the voltage drop from motor 2 leakage inductance as a percentage of Motor Rated Voltage when
motor 2 operates at the rated frequency and rated current.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor 2 iron-core saturation coefficient at 50% of the magnetic flux.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor 2 iron-core saturation coefficient at 75% of the magnetic flux.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the mechanical loss of motor 2. It is set as a percentage of E4-11 [Motor 2 Rated Power].
Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor iron loss for motor 2.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor rated power in the units from o1-58 [Motor Power Unit Selection].
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance & Troubleshooting
Default
(Range)
Determined by E3-01
(200 V Class: 0.0 - 255.0 V,
400 V Class: 0.0 - 510.0 V)
Determined by E3-01
(0.0 - E3-04)
Determined by E3-01
(0.0 - E3-04)
Determined by E3-01
(200 V Class: 0.0 - 255.0 V,
400 V Class: 0.0 - 510.0 V)
Determined by E3-01
(0.0 - E3-04)
Determined by E3-01
(200 V Class: 0.0 - 255.0 V,
400 V Class: 0.0 - 510.0 V)
0.0 Hz
(0.0 - E3-04)
0.0 V
(200 V Class: 0.0 to 255.0 V,
400 V Class: 0.0 to 510.0 V)
0.0 V
(200 V Class: 0.0 to 255.0 V,
400 V Class: 0.0 to 510.0 V)
Default
(Range)
Determined by o2-04, C6-01
(10% to 200% of the drive
rated current)
Determined by o2-04, C6-01
(0.000 - 20.000 Hz)
Determined by o2-04, C6-01
(Less than 0 - E4-01)
4
(2 - 120)
Determined by o2-04, C6-01
(0.000 - 65.000 Ω)
Determined by o2-04, C6-01
(0.0 - 60.0%)
0.50
(0.00 - 0.50)
0.75
(E4-07 - 0.75)
0.0%
(0.0 - 10.0%)
Determined by o2-04, C6-01
(0 - 65535 W)
Determined by o2-04, C6-01
(0.00 - 650.00 HP)