U4: Maintenance Monitors - YASKAWA GA800 Maintenance & Troubleshooting

Ac drive for industrial applications, three-phase 200/400 v class: 1 to 150/600 hp, 6-phase/12-pulse 400 v class: 75 to 600 hp
Hide thumbs Also See for GA800:
Table of Contents

Advertisement

3.17 U: Monitors
No.
Name
(Hex.)
U3-16
ElapsedTime@6thFault
(080F)
U3-17
ElapsedTime@7thFault
(0810)
U3-18
ElapsedTime@8thFault
(0811)
U3-19
ElapsedTime@9thFault
(0812)
U3-20
ElapsedTime@10 Fault
(0813)

U4: Maintenance Monitors

No.
Name
(Hex.)
U4-01
Cumulative Ope Time
(004C)
U4-02
Num of Run Commands
(0075)
U4-03
Cooling Fan Ope Time
(0067)
U4-04
Cool Fan Maintenance
(007E)
U4-05
CapacitorMaintenance
(007C)
262
V/f
CL-V/f
OLV
CLV
AOLV
Shows the cumulative operation time when the sixth most recent fault occurred.
Unit: 1 h
V/f
CL-V/f
OLV
CLV
AOLV
Shows the cumulative operation time when the seventh most recent fault occurred.
Unit: 1 h
V/f
CL-V/f
OLV
CLV
AOLV
Shows the cumulative operation time when the eighth most recent fault occurred.
Unit: 1 h
V/f
CL-V/f
OLV
CLV
AOLV
Shows the cumulative operation time when the ninth most recent fault occurred.
Unit: 1 h
V/f
CL-V/f
OLV
CLV
AOLV
Shows the cumulative operation time when the tenth most recent fault occurred.
Unit: 1 h
V/f
CL-V/f
OLV
CLV
AOLV
Shows the cumulative operation time of the drive.
Use parameter o4-01 [Elapsed Operating Time Setting] to reset this monitor. Use parameter o4-02
[Elapsed Operating Time Selection] to select the cumulative operation times from:
• The time from when the drive is energized until it is de-energized.
• The time at which the Run command is turned ON.
The maximum value that the monitor will show is 99999. After this value is more than 99999, the
drive automatically resets it and starts to count from 0 again.
Unit: 1 h
Note:
The MEMOBUS/Modbus communication data is shown in 10 h units. Use register 0099H for
data in 1 h units.
V/f
CL-V/f
OLV
CLV
AOLV
Shows how many times that the drive has received a Run command.
Use parameter o4-13 [RUN Command Counter @ Initialize] to reset this monitor. The maximum
value that the monitor will show is 65535. After this value is more than 65535, the drive
automatically resets it and starts to count from 0 again.
Unit: 1
V/f
CL-V/f
OLV
CLV
AOLV
Shows the cumulative operation time of the cooling fans.
Use parameter o4-03 [Fan Operation Time Setting] to reset this monitor. The maximum value that
the monitor will show is 99999. After this value is more than 99999, the drive automatically resets it
and starts to count from 0 again.
Unit: 1 h
Note:
The MEMOBUS/Modbus communication data is shown in 10 h units. Use register 009BH for
data in 1 h units.
V/f
CL-V/f
OLV
CLV
AOLV
Shows the cumulative operation time of the cooling fans as a percentage of the replacement life of
the cooling fans.
Use parameter o4-03 [Fan Operation Time Setting] to reset this monitor.
Unit: 1%
Note:
Replace the cooling fans when this monitor is 90%.
V/f
CL-V/f
OLV
CLV
AOLV
Shows the operation time of the electrolytic capacitors for the main circuit and control circuit as a
percentage of the replacement life of the electrolytic capacitors.
Use parameter o4-05 [Capacitor Maintenance Setting] to reset this monitor.
Unit: 1%
Note:
Replace the electrolytic capacitor when this monitor is 90%.
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
YASKAWA TOEPYAIGA8001B GA800 Drive Maintenance & Troubleshooting
MFAO Signal Level
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
MFAO Signal Level
10 V: 99999 h
10 V: 65535 times
10 V: 99999 h
10 V: 100%
10 V: 100%

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents