For Encoder; Cn Ser Connector - Panasonic MINAS S Series Operating Manual

Ac servo motor driver
Hide thumbs Also See for MINAS S Series:
Table of Contents

Advertisement

CN SIG Connector (For Encoder)
figure shown left. 6) Other terminals should be left

CN SER Connector

For RC232C communications
Connect a personal computer to the amplifier with RS232C at 1:1, and use the communication
control software "PANATERM"" (Option). Operate "PANATERM"" on the personal computer.
The cable length between the amplifier and
motor should be max. 20 m. If you use a
longer cable, contact the dealer or sales
agent.
Separate these wiring min. 30 cm from the
main circuit wires. Don't lay these wires in
the same duct of the mains or bundle with
them.
When you prepare your own connecting cables
see the "Optional Parts"
for connectors, and
1)
Follow the wiring diagram and use the
2)
Wire material: 0.18 mm
more, shielded twist-paired wire Å@with an
enough bending durability,
3)
Signal/power paired wires should be of
atwist-paired type.
4)
Shield:
The shield at the amplifier side should
beconnected to Pin 20 (FG) of CN SIG
Connector.
The shield at the motor side should be
con-nected to: connector of 15 pins type
5) If the cable is longer than 10 m, the encoder
power line (+5V and 0V) should be dual per the
unconnected.