Panasonic MINAS S Series Operating Manual page 22

Ac servo motor driver
Hide thumbs Also See for MINAS S Series:
Table of Contents

Advertisement

Motor cable
Brake cable
( Motor with electromag -
netic brake only )
<Notes>
For detailed information for each of motor types, see the drawings in the Appendix (App.48
& 49).
Installation
The amplifier and motor should be properly installed to avoid failures, mechanical damages
and injuries.
Amplifier
Location
• Indoors, where the amplifier is not subjected to rain water and direct sun beams. Note that
the amplifier is not a waterproof structure.
• Avoid the place where the amplifier is subjected to corrosive gases, flammable gases,
grinding liquids, oil mists, iron powders and cutting particles.
• Place in a well-ventilated, and humid- and dust-free space.
• Place in a vibration-free space.
Environmental Conditions
Item
Ambient temperature
Ambient humidity
Storage temperature
Encoder cable
Frame
Flange
0 to 55˚C (free from freezing)
Not greater than 90%RH (free from condensation)
-20 to 80˚C (free from condensation)
-21-
Encoder
Mounting bolt holes (4)
Conditions