After an Alarm event (during Servo-ON)
Alarm
Normal
Dynamic brake
Motor energized
Energized
Servo alarm
Not alarm
(
ALM
)
Brake release
Released (ON)
( BRK-OFF
)
A
approx. 30
r/min
Released (ON)
B
approx. 30
r/min
*1. The value of t1 is the value of Pr6B or the time needed for decreasing the motor speed to
approx. 30 r/min, which is shorter.
*2. For the operation of the dynamic brake following an alarm event, see the explanation of
Pr68 in "Details of Parameters".
approx.1 to 5 ms
Set by Pr6B
Operation (OFF)
t1
1
Set by Pr6B
t1
1
Operation (OFF)
- App. 13 -
Error (alarmed)
Operation (braking) 2
Not energized
Alarm