Advertisement

List of Available Components
CN I/F Connector (For Controller)
Place the peripheral devices such as the controller
max. 3 m away from the amplifier.
Separate these wiring min. 30 cm from the main
circuit wires. Don't lay these wires in the same
duct of the mains or bundle with them.
The control power (VDC) between COM+ and
COM- should be supplied by the customer
(recommended voltage: +12VDC to +24VDC).
Use a shielded twist-paired type for the wiring of
pulse input, encoder signal output, etc.
Do not apply power higher than 24V or 50mA to
control signal output terminal.
If you directly activate a relay using the control
signal,install a diode in parallel to the relay as
shown in the left figure. Without a diode or with it
but placed in the opposite direction, the amplifier
will be damaged.
The Frame Ground (FG) is connected to an earth
terminal in the amplifier.
• CN I/F Connector Specifications
Receptacle on the
Connector to controller side
Manufacturer
amplifier side
Part description
Part No.
1 0 2 2 6 - 5 2 A 2 J L
Solder type plug
1 0 1 2 6 - 3 0 0 0 V E
Sumitomo
(Soldering type)
three M
- 35 -