M120 Multiservice Edge Router Hardware Guide
Action
114
All manuals and user guides at all-guides.com
On a regular basis:
Check the LEDs on the FEB faceplate. For more information on the FEB LEDs, see Table
5 on page 17.
Check the FEB LEDs on the craft interface to view information; see Table 11 on page 27.
Issue the CLI
show chassis feb
FEBs. As shown in the sample output, the value
indicates that the FEB is functioning normally.
user@host> show chassis feb
(%)
Slot State
Buffer
0
Empty
1
Empty
2
Online
63
3
Online
63
4
Online
63
5
Online
63
For more detailed output, add the
a slot number (
), which is optional:
0
user@host> show chassis feb detail 0
Slot 0 information:
State
Intake temperature
Exhaust A temperature
Exhaust B temperature
Total DDR DRAM
Total RLDRAM
Start time:
Uptime:
You can also issue the
show chassis environment feb
a specific FEB. In the example below, the FEB is slot
the following:
user@host> show chassis environment feb 0
FEB 0 status:
State
Temperature Intake
Temperature Exhaust A
Temperature Exhaust B
Power
1.2 V
1.5 V
1.8 V
2.5 V
3.3 V
5.0 V
command to check the status of each of the installed
in the column labeled
Online
Temp
CPU Utilization (%)
(C)
Total
Interrupt
44
4
0
46
4
0
45
3
0
42
4
0
option. The following example also specifies
detail
Online
66 degrees C / 150 degrees F
67 degrees C / 152 degrees F
73 degrees C / 163 degrees F
512 MB
64 MB
2006-09-08 16:29:59 PDT
1 hour, 3 minutes, 4 seconds
command to check the status of
0
is used. The output is similar to
Online
66 degrees C / 150 degrees F
67 degrees C / 152 degrees F
73 degrees C / 163 degrees F
1153 mV
1417 mV
1704 mV
2375 mV
3138 mV
4763 mV
Copyright © 2010, Juniper Networks, Inc.
State
Memory
Utilization
DRAM (MB) Heap
512
7
512
7
512
7
512
7

Advertisement

Table of Contents
loading

Table of Contents