Time Chart
The time chart when using the UP/DOWN command is shown below.
Output frequency
Forward operation/stop
DOWN command
Frequency
matching signal*
Jog Frequency Operation without Forward and Reverse Commands
(FJOG/RJOG)
The FJOG/RJOG command functions operate the Inverter using jog frequencies by using the terminal on/off
operation. When using the FJOG/RJOG commands, there is no need to input the Run Command.
To use this function, set one of the constants H1-03 to H1-16 (multi-function contact input terminal S3 to S16
function selection) to 12 (FJOG command) or 13 (RJOG command).
Related Constants
Constant
Number
d1-17
-46
6
Upper limit
Accelerates to
lower limit
Lower limit
On
UP command
On
Power supply
* The frequency matching signal turns on when the motor is not accelerating/
decelerating while the Run Command is on.
Fig 6.22 UP/DOWN Commands Time Chart
Name
Description
Display
Jog frequency
The frequency reference when
reference
the jog frequency reference
selection, FJOG command, or
Jog Reference
RJOG command is on.
Same
frequency
On
Reference
frequency reset
On
On
Setting
Factory
Range
Setting
0.00 to
10.00%
100.00
On
Control
Change
Methods
MEMOBUS
during
Open-
Register
Flux
Operation
loop
Vector
Vector
Yes
Q
Q
2D0H