Intel® Sas Raid Module Removal; Figure 86. Intel® Sas Raid Module Removal - Intel M50CYP2UR Series System Integration And Service Manual

Table of Contents

Advertisement

Intel® Server System M50CYP2UR Family System Integration and Service Guide
3.11.4
Intel® SAS RAID Module Removal
1.
Power off the system and disconnect the power cable(s).
2.
Remove the system top cover (see
3.
Remove the air duct (see
4.
Disconnect all the cables connected to the SAS RAID module.
5.
Remove the four locking pins from each standoff (see Letter A).
6.
Grasp the SAS RAID module on both sides and lift firmly until the connector is disengaged from the
matching connector on the SAS interposer card (see Letter B).
7.
Remove the standoffs (see Letter C), if not installing another SAS RAID module on the SAS interposer
card. Keep the standoffs, locking pins, and the SAS RAID module together.
8.
Reinstall the air duct (see
9.
Reinstall the system top cover (see
76
Figure 86. Intel® SAS RAID Module Removal
Section
3.1.1).
Section
3.2.1).
Section
3.2.2).
Section
3.1.2).