3.11 Intel® Virtual Raid On Cpu (Intel® Vroc) Upgrade Key Installation/Removal; Figure 69. Intel® Vroc Upgrade Key Installation - Intel D40AMP Series Integration And Service Manual

Table of Contents

Advertisement

3.11 Intel® Virtual RAID on CPU (Intel® VROC) Upgrade Key Installation/Removal
Required Tools and Supplies:
Anti-static wrist strap and conductive workbench pad (recommended)
1. Remove the module to be serviced from the server chassis and place it on an anti-static work surface (see
Section
3.3.1).
2. Remove the riser assembly from the Riser Slot 2 (see
3. Remove the Intel® VROC Upgrade Key from its packaging.
4. Locate the white 4-pin key connector near the right edge of the server board.
5. Place the key over the connector and confirm that the orientation of the key matches that of the
connector.
6. Press the key down onto the connector.
7. Removal of the Intel® VROC Upgrade Key must be done by pulling it out of the board using the attached
loop.
58
Intel® Server D40AMP Family Integration and Service Guide
Figure 69. Intel® VROC Upgrade Key Installation