System Cover Installation; Air Duct Removal / Installation; Figure 4. System Top Cover Installation - Intel M50CYP2UR Series System Integration And Service Manual

Table of Contents

Advertisement

Intel® Server System M50CYP2UR Family System Integration and Service Guide
2.2.2

System Cover Installation

For each top cover panel:
1.
Carefully align and set the top cover panel on top of the chassis. Then, slide it inwards until it locks into
place (see Letter A).
Shipping Note: When transporting the server system, Intel recommends installing the four top cover screws
before shipping.
2.3

Air Duct Removal / Installation

Required Tools and Supplies
Anti-static wrist strap and conductive workbench pad (recommended)
The Intel® Server System M50CYP2U family has three types of air ducts. The type used depends on the
processor heat sink and add-in cards installed in the system:
Standard air duct for processor heat sink with 2U height
Standard air duct for processor heat sink with 1U height
General Purpose Graphics Processing Unit (GPGPU) air duct for processor heat sink with 1U height
Note: Always operate the server system with the air duct in place. The air duct is required for proper airflow
within the server system.