System Service And Fru Replacement; System Cover Removal / Installation - Intel M50CYP2UR Series System Integration And Service Manual

Table of Contents

Advertisement

Intel® Server System M50CYP2UR Family System Integration and Service Guide
6.

System Service and FRU Replacement

This chapter provides instruction for replacement of system components considered to be field replaceable
(FRU). Only system features that are identified as hot-swappable can be replaced while the system remains
operational. These items include:
Power Supply – In dual power supply configurations only
Drives mounted within the front drive bay – Redundant RAID (1, 5, 6, and 10) configurations only
System Fans
All other components within the system can only be serviced after the system has been powered off and AC
power cords have been disconnected from the server system.
Before You Begin
Before integration of any system components, review all the safety and ESD precautions found in the Safety
Warnings section at the beginning of this document.
System Reference
In the following procedures, all references to left, right, front, top, and bottom assume the reader is facing
the front of the server chassis.
Instruction Format
Each procedure described in this chapter follows an illustration first format. This format gives the reader the
option to follow a quicker path to component integration by first seeing an illustration of the intended
procedure. If necessary, the reader can then follow the step-by-step instructions that accompany each
procedure.
6.1

System Cover Removal / Installation

The system top cover consists of two panels – one over the front half of the system and one over the back
half of the system. To maintain system thermals, both top cover panels must always be in place when the
system is operational.
Required Tools and Supplies
Anti-static wrist strap and conductive workbench pad (recommended)
Phillips* head screwdriver #1
90