Intel® Sas Interposer Card Removal; Figure 84. Sas Interposer Card Removal - Intel M50CYP2UR Series System Integration And Service Manual

Table of Contents

Advertisement

Intel® Server System M50CYP2UR Family System Integration and Service Guide
3.11.2
Intel® SAS Interposer Card Removal
1.
Power off the system and disconnect the power cable(s).
2.
Remove the system top cover (see
3.
Remove the air duct (see
4.
If an installed RAID module needs to be removed (see
5.
Disconnect all the connectors attached to the SAS interposer card.
6.
Unscrew the four (4) screws on the SAS interposer card (see Letter A).
7.
Lift the SAS interposer card from the chassis all the way out (see Letter B).
8.
Reinstall the air duct (see
9.
Reinstall the system top cover (see
74

Figure 84. SAS Interposer Card Removal

Section
3.1.1).
Section
3.2.1).
Section
3.2.2).
Section
3.1.2).
Section
3.11.4).

Advertisement