Intel® Server System M50CYP2UR Family System Integration and Service Guide
6.8.1
2.5" SSD Drive Removal
1. Press the button on the drive extraction lever to release it (see Letter A).
2. Using the lever, pull the drive mounting rail part way out of the drive bay (see Letter B).
Note: The 2.5" drive mounting rail cannot be pulled all the way out of the chassis. Only pull it as much as
it allows without forcing it.
3. Remove the drive (or drive blank) from the drive mounting rail (see Letter C).
6.8.2
2.5" SSD Drive Assembly for 7 mm Drives
The Intel® Server System M50CYP2UR family supports 2.5" SSDs with 7 mm of thickness when used in
conjunction with the supplied blanks. The supplied blank for 2.5" bays has two parts: top and bottom. The
top part must be attached to the 7 mm drive to fit properly inside the 2.5" bay. The following provides
instructions to attach the supplied blank part to a 7 mm thick SSD. The 2.5" SSDs with 15-mm thick drive do
not require any assembly with the top part of the drive blank.
1. Remove the drive blank from the system (see
2. Press the handles at the bottom part of the drive blank (see Letter A).
3. Separate the top and bottom parts while pressing the handles (see Letter B).
110
Figure 142. Drive Removal
Figure 143. Separating Top and Bottom Parts of Drive Blank
Section
6.8.1).