Drive Removal, Installation, And Assembly; Figure 139. Tighten Heat Sink Fasteners - Intel M50CYP2UR Series System Integration And Service Manual

Table of Contents

Advertisement

Intel® Server System M50CYP2UR Family System Integration and Service Guide
7. Tighten the heat sink fasteners using a T30 Torx* screwdriver to 8 in-lb. No specific sequence is needed
for tightening.
8. Reinstall the air duct (see
9. Reinstall system top cover (see
Important: Do not install a processor heat sink on an empty socket. Also, only install a socket cover on an
empty socket
6.8

Drive Removal, Installation, and Assembly

The Intel® Server System M50CYP2UR family has front drive bay options that support 2.5" form factor drives
(Solid State Drives only) or 3.5" form factor hard disk drives. Additionally, 7 mm thick SSDs with a form factor
of 2.5" are supported when used in conjunction with the supplied drive blank for 2.5" bays. Each storage
drive that interfaces with a backplane is mounted to a tool-less hot swap drive mounting rail (2.5" drive) /
drive carrier (3.5" drive).
This section provides instructions for drive removal from the chassis, drive installation into the chassis, and
drive assembly for specific types of supported drives. For drive population rules, see the Intel® Server System
M50CYP2UR Family Technical Product Specification (TPS).
The Intel® Server System M50CYP2UR family has front drive bay chassis options that support
2.5" form factor drives (Solid State Drives only) or
3.5" form factor hard disk drives with the option to support 2.5" SSDs.
Required Tools and Supplies
Anti-static wrist strap and conductive workbench pad (recommended)
Phillips* head screwdriver #1
108