Intel® Server System M50CYP2UR Family System Integration and Service Guide
8. Reinstall the riser card assembly as needed (see
9. Reinstall the air duct (see
10. Reinstall the system top cover (see Section3.1.2).
3.5.7

OCP* Adapter with Internal Lock Removal

1. Remove the system top cover (see
2. Remove any riser card assembly above the OCP* adapter area, if present (see
3. Squeeze the two hooks of the internal lock and pull it out (see Letter A).
4. Install it back in the chassis in reverse orientation (see Letter B).
5. Push the OCP* adapter out of the bay from inside the chassis (see Letter C).
6. Reinstall the riser card assembly as needed (see
7. Reinstall the air duct (see
8. Reinstall the system top cover (see
3.6

M.2 Storage Device Installation / Removal

The server board includes two M.2 connectors as shown in the following figure. Each M.2 connector supports
a PCIe* NVMe or SATA SSD drive that conforms to a 22110 (110 mm) or 2280 (80 mm) form factor.
Required Tools and Supplies
Anti-static wrist strap and conductive workbench pad (recommended)
Phillips* head screwdriver #1
62
Section
3.2.2).

Figure 68. OCP* Adapter with Internal Lock Removal

Section
2.2.1).
Section
3.2.2).
Section
3.1.2).
Section
3.3.4).
Section
3.3.4)
Section
3.3.1)