Delta Electronics ASDA-A2 Series User Manual page 367

High resolution ac servo drive for network communication applications
Table of Contents

Advertisement

Call 1(800)985-6929 for Sales
Chapter 8 Servo Parameters
P4 - 21
DOF2
Default: Factory setting
Applicable Control Mode: ALL
Unit: mV
Range: -800 ~ 800
Data Size: 16-bit
Display Format: Decimal
Settings:
Please note that when P2-08 is set to 10, the users cannot reset this parameter.
P4 - 22
SAO
Default: 0
Applicable Control Mode: S
Unit: mV
Range: -5000 ~ 5000
Data Size: 16-bit
Display Format: Decimal
Settings:
In speed mode, the users can use this parameter to add an offset value to analog speed
input.
P4 - 23
TAO
Default: 0
Applicable Control Mode: T
Unit: mV
Range: -5000 ~ 5000
Data Size: 16-bit
Display Format: Decimal
Settings:
In speed mode, the users can use this parameter to add an offset value to analog speed
input.
8-122
Call 1(800)985-6929 for Sales
deltaacdrives.com
Analog Monitor Output Drift Adjustment
(CH2)
Analog Speed Input Offset
Analog Torque Input Offset
deltaacdrives.com
sales@deltaacdrives.com
Address: 042AH, 042BH
Related Section:
Section 6.4.4
Address: 042CH, 042DH
Related Section: N/A
Address: 042EH, 042FH
Related Section: N/A
Revision January 2011