Delta Electronics ASDA-A2 Series User Manual page 315

High resolution ac servo drive for network communication applications
Table of Contents

Advertisement

Call 1(800)985-6929 for Sales
Chapter 8 Servo Parameters
Display Format: Decimal
Settings:
This parameter is used to set the capacity of the applicable regenerative resistor.
For
models
For 2kW to 4.5kW models
5.5kW
P1 - 54
PER
Default: 12800
Applicable Control Mode: PT , PR
Unit: pulse
Range: 0 ~ 1280000
Data Size: 32-bit
Display Format: Decimal
Settings:
In PT mode, when the error pulse numbers is less than the setting value of parameter
P1-54, TPOS (At positioning completed signal) will be activated.
In PR mode, when the difference in pulse number between the target position and the
actual position is less than the setting value of parameter P1-54, TPOS (At positioning
completed signal) will be activated.
P1 - 55
MSPD
Default: rated speed
Applicable Control Mode: ALL
Unit: r/min
Range: 0 ~ Max. speed
Data Size: 16-bit
Display Format: Decimal
Settings:
This parameter is used to set maximum motor speed. The default setting is rated speed.
8-70
Call 1(800)985-6929 for Sales
deltaacdrives.com
Model
1.5kW
and
below
Positioning Completed Width
Maximum Speed Limit
deltaacdrives.com
Default
60W
100W
0W
sales@deltaacdrives.com
Address: 016CH, 016DH
Related Section: Table 8.A
Address: 016EH, 016FH
Related Section: N/A
Revision January 2011
sales@deltaacdrives.com

Advertisement

Table of Contents
loading

Table of Contents