Delta Electronics ASDA-A2 Series User Manual page 354

High resolution ac servo drive for network communication applications
Table of Contents

Advertisement

Call 1(800)985-6929 for Sales
P3 - 05
CMM
Default: 0
Applicable Control Mode: ALL
Unit: N/A
Range: 0x00 ~ 0x01
Data Size: 16-bit
Display Format: Hexadecimal
Settings:
Communication interface selection
0: RS-232
1: RS-485
Multiple communication modes RS232 and RS-485 cannot be used within one
communication ring. Point-to-point connection or multidrop connection can be selected.
P3 - 06 
SDI
Default: 0
Applicable Control Mode: ALL
Unit: N/A
Range: 0x0000 ~ 0x3FFF
Data Size: 16-bit
Display Format: Hexadecimal
The setting of this parameter determines how the Digital Inputs (DI) accept commands
and signals.
Bit0 ~ Bit 7 corresponds with DI1 ~ DI8. The least significant bit (Bit0) shows DI1 status
and the most significant bit (Bit7) shows DI8 status.
Bit8 ~ Bit14 corresponds with EDI9 ~ EDI14.
Bit settings:
0: Digital input is controlled by external command (via CN1)
1: Digital input is controlled by parameter P4-07
For the settings of DI1 ~ DI8, please refer to P2-10 ~ P2-17.
For the settings of EDI9 ~ EDI14, please refer to P2-36 ~ P2-41.
This parameter P3-06 also works in conjunction with the parameter P4-07 which has
several functions. Please see section 9.2 for details.
Revision January 2011
Call 1(800)985-6929 for Sales
deltaacdrives.com
Communication Selection
Digital Input Communication Function
deltaacdrives.com
sales@deltaacdrives.com
Chapter 8 Servo Parameters
Address: 030AH, 030BH
Related Section: Section 9.2
Address: 030CH, 030DH
Related Section: Section 9.2
8-109
sales@deltaacdrives.com

Advertisement

Table of Contents
loading

Table of Contents