Chapter 8 Servo Parameters
P1 - 13
TQ2
Default: 100
Applicable Control Mode: T, P&S
Unit: %
Range: -300 ~ +300
Data Size: 16-bit
Display Format: Decimal
Settings:
2nd Torque Command
In Torque mode, this parameter is used to set torque 2 of internal torque command.
2nd Torque Limit
In Position and Speed mode, this parameter is used to set torque limit 2 of internal
torque command.
Digital output signal TQL is activated when the drive has detected that the motor has
reached the torques limits set by either the parameters P1-12 ~ P1-14 of via an external
analog voltage.
P1 - 14
TQ3
Default: 100
Applicable Control Mode: T, P&S
Unit: %
Range: -300 ~ +300
Data Size: 16-bit
Display Format: Decimal
Settings:
3rd Speed Command
In Torque mode, this parameter is used to set torque 3 of internal torque command.
3rd Speed Limit
In Position and Speed mode, this parameter is used to set torque limit 3 of internal
torque command.
Digital output signal TQL is activated when the drive has detected that the motor has
reached the torques limits set by either the parameters P1-12 ~ P1-14 of via an external
analog voltage.
P1 - 15
Reserved (Do Not Use)
P1 - 16
Reserved (Do Not Use)
P1 - 17
Reserved (Do Not Use)
8-56
Call 1(800)985-6929 for Sales
deltaacdrives.com
2nd Torque Command or Limit
3rd Torque Command or Limit
deltaacdrives.com
sales@deltaacdrives.com
Address: 011AH, 011BH
Related Section:
Section 6.4.1
Address: 011CH, 011DH
Related Section:
Section 6.4.1