Setting The Automatic Refresh Parameters Of The Master Station - Mitsubishi MELSEC-Q Series User Manual

Cc-link system master/local module, mitsubishi programmable logic controller
Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

10 COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE
DEVICE STATIONS

10.2.2 Setting the automatic refresh parameters of the master station

10 - 6
(1) Setting the automatic refresh parameters
Set the automatic refresh parameters according to the procedure below.
(a) Set the refresh device for remote input (RX) to X1000.
(b) Set the refresh device for remote output (RY) to Y1000.
(c) Set the refresh device for remote register (RWr) to D1000.
(d) Set the refresh device for remote register (RWw) to D2000.
(e) Set the refresh device for special relay (SB) to SB0.
(f)
Set the refresh device for special register (SW) to SW0.
POINT
When setting the refresh devices for special relay (SB) and special register (SW) to
SB and SW, respectively, make sure that they do not overlap with device numbers
used in the MELSECNET/H network.
(2) Setting example
A setting example is shown below.
MELSEC-Q
10 - 6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qj61bt11

Table of Contents