4 FUNCTIONS
Master station (standby)
Station number 0
1
Number of occupied stations: 1
Remote
Remote
input RX
output RY
RX00 to RX0F
RY00 to RY0F
RX10 to RX1F
RY10 to RY1F
RX20 to RX2F
RY20 to RY2F
RX30 to RX3F
RY30 to RY3F
RX40 to RX4F
RY40 to RY4F
RX50 to RX5F
RY50 to RY5F
Master station (standby)
Station number 0
1
Number of occupied stations: 1
Remote
Remote
input RX
output RY
RX00 to RX0F
RY00 to RY0F
RX10 to RX1F
RY10 to RY1F
RX20 to RX2F
RY20 to RY2F
RX30 to RX3F
RY30 to RY3F
RX40 to RX4F
RY40 to RY4F
RX50 to RX5F
RY50 to RY5F
4 - 34
(c) When the master station has returned to system operation and the standby
master station is controlling the data link
1) Standby master station output
Standby master station
(controlling)
Station number 0
Remote
Remote
input RX
output RY
RX00 to RX0F
RY00 to RY0F
RX10 to RX1F
RY10 to RY1F
RX20 to RX2F
RY20 to RY2F
RX30 to RX3F
RY30 to RY3F
RX40 to RX4F
RY40 to RY4F
RX50 to RX5F
RY50 to RY5F
Data sent from the standby master station to the remote input RX and
remote register RWr in the standby master station (shown by the shaded
areas in the figure above) is used as output data when the master
station becomes faulty; it should be saved in another device using the
sequence program.
When the standby master station becomes faulty, the saved data is
transferred to the remote output RY and remote register RWw in the
master station using the sequence program.
2) Standby master station input
Standby master station
(controlling)
Station number 0
Remote
Remote
input RX
output RY
RX00 to RX0F
RY00 to RY0F
RX10 to RX1F
RY10 to RY1F
RX20 to RX2F
RY20 to RY2F
RX30 to RX3F
RY30 to RY3F
RX40 to RX4F
RY40 to RY4F
RX50 to RX5F
RY50 to RY5F
Data sent to the remote output RY and remote register RWw in the
master station is being used as input data by the master station when
local stations are operating; thus, it does not need to be saved in another
device.
Remote I/O station
Station number 2
Number of occupied stations: 1
X00 to X0F
Y00 to Y0F
X10 to X1F
Y10 to Y1F
Remote I/O station
Station number 2
Number of occupied stations: 1
X00 to X0F
Y00 to Y0F
X10 to X1F
Y10 to Y1F
MELSEC-Q
Remote I/O station
Station number 3
Number of occupied stations: 1
X00 to X0F
Y00 to Y0F
X10 to X1F
Y10 to Y1F
Remote I/O station
Station number 3
Number of occupied stations: 1
X00 to X0F
Y00 to Y0F
X10 to X1F
Y10 to Y1F
4 - 34