About the Generic Terms and Abbreviations

This manual uses the following generic terms and abbreviations to describe the QJ61BT11 Control &
Communication Link System Master/Local Module, unless otherwise specified.
Generic Term/Abbreviation
QJ61BT11
Cyclic transmission
Transient transmission
Master station
Local station
Remote I/O station
Remote device station
Remote station
Intelligent device station
Standby master station
Master/local module
Master module
Local module
Remote module
Intelligent device module
Remote I/O net mode
Remote net mode
SB
SW
RX
RY
A - 12
Abbreviation for QJ61BT11 Control & Communication Link System Master/Local
Module
Transmission method by which to periodically communicate the contents of remote
I/O and remote registers.
Transmission method with which the counterpart is specified and 1:1 communication
is used at an arbitrary timing.
Station that controls the data link system.
One master station is required for each system.
Station having a PLC CPU and the ability to communicate with the master and other
local stations.
Remote station that handles bit unit data only. (Performs input and output with
external devices.) (AJ65BTB1-16D, AJ65SBTB1-16D)
Remote station that handles bit unit and word unit data only. (Performs input and
output with external devices, and analog data conversion.)
(AJ65BT-64AD, AJ65BT-64DAV, AJ65BT-64DAI)
Generic term for remote I/O station and remote device station.
(Controlled by the master station)
Station that can perform transient transmission, such as the AJ65BT-R2 (including
local stations).
Backup station for data link control when the link to the master station is disconnected
due to a PLC CPU or power supply problem.
Generic term for QJ61BT11, AJ61BT11, A1SJ61BT11, AJ61QBT11, and
A1SJ61QBT11
Generic term for QJ61BT11, AJ61BT11, A1SJ61BT11, AJ61QBT11, and
A1SJ61QBT11 when they are used as master stations.
Generic term for QJ61BT11, AJ61BT11, A1SJ61BT11, AJ61QBT11, and
A1SJ61QBT11 when they are used as local stations.
Generic term for AJ65BTB1-16D, AJ65SBTB1-16D, AJ65BT-64AD, AJ65BT-64DAV,
AJ65BT-64DAI, and A852GOT
Module that can perform transient transmission, such as the AJ65BT-R2 (including
local module).
Dedicated mode for sending and receiving data to and from the remote I/O station at
high speed.
Mode that can communicate with all stations used for CC-Link (remote I/O station,
remote device station, local station, intelligent device station, and standby master
station)
Link special relay (for CC-Link)
Bit unit information that indicates the module operating status and data link status of
the master station/local station. (Expressed as SB for convenience)
Link special register (for CC-Link)
16-bit unit information that indicates the module operating status and data link status
of the master station/local station. (Expressed as SW for convenience)
Remote input (for CC-Link)
Information entered in bit units from the remote station to the master station.
(Expressed as RX for convenience)
Remote output (for CC-Link)
Information output in bit units from the master station to the remote station.
(Expressed as RY for convenience)
Description