4 FUNCTIONS
4 - 45
2) Execute Flag
Set whether or not to execute the specified initialization procedure.
Setting range: Execute
Only set (use as a memo when the execution conditions
are the same as when the execution flag is set as
"Execute", but the content of execution is different.)
Default:
Execute
3) Operational condition
Specify whether new settings or the previous settings are used for the
initialization conditions.
Setting range: Set new
Same as prev. set
Default:
Set new
When "Same as prev. set" is selected, the processing is performed as
follows:
Example)
RX1
0
4) Executional condition settings "Condition Device"
Set the device to be used for the initialization condition.
Setting range: RX
SB
5) Executional condition settings "Device Number"
Set the device number to be used for the initialization condition.
Setting range: When RX is selected 0 to 7F (H)
When SB is selected 0 to FF (H)
6) Executional condition settings "Execute Condition"
Set the conditions under which initialization is performed.
Setting range: ON
OFF
7) Details of execution "Write Device"
Set the device to which the contents of the initial setting are written.
Setting range: RY
RWw
8) Details of execution "Device Number"
Set the device number to which the contents of the initial settings are
written.
Setting range: When RY is selected
When RWw is selected
MELSEC-Q
SET
RY3
M0V
K15
RWw2
0 to 7F (H)
0 to 0F (H)
4 - 45