8 PROGRAMMING
Number
Name
SW0045
Data link stop result
(645
)
H
Temporary error
SW0049
invalid station
(649
)
H
specification result
Temporary error
SW004B
invalid station
(64B
)
specification cancel
H
result
SW004D
Line test result
(64D
)
H
SW004F
Parameter setting test
(64F
)
result
H
Automatic CC-Link
SW0052
4
startup execution
(652
)
H
result
SW0058
Detailed LED display
(658
)
status
H
SW0059
Transmission rate
(659
)
setting
H
4: The link special register added in QJ61BT11 of the function version B.
8 - 23
Table 8.4 Link special register list (2/7)
Description
Stores the execution result of the data-link stop instruction with
SB0002.
0
: Normal
Other than 0: Stores the error code (see Section 13.3).
Indicates the execution result of temporary error invalid station
specification.
0
: Normal
Other than 0: Stores the error code (see Section 13.3).
Indicates the execution result of the temporary error invalid station
specification cancellation.
0
: Normal
Other than 0: Stores the error code (see Section 13.3).
Indicates the execution result of the line test.
0
: Normal
Other than 0: Stores the error code (see Section 13.3).
Indicates the execution result of the parameter setting test.
0
: Normal
Other than 0: Stores the error code (see Section 13.3).
Stores the system configuration check result when a new station is
added to a system using an automatic CC-Link startup.
0: Normal
Other than 0: Stores the error code (see Section 13.3.)
Stores the details of the LED display status.
0: OFF
1: ON
b15 b14b13 b12 b11
b10
b9
b8 b7 b6 b5 b4
b3
b2 b1 b0
0
0
0
0
0
0
LINE(ERROR) : Cable is disconnected or the
TIME(ERROR): Responses cannot be received from
PRM(ERROR) : Invalid parameter value
M/S(ERROR) : Duplicate master station on the
SW(ERROR) : Error in switch settings
LOCAL
S MST
MST
ERR.
RUN
Stores the contents of the transmission rate setting.
0: Cancel
1: Set
b15
b8
b7 b6 b5 b4 b3
0
0
to
Master station
transmission path is affected by
noise.
any station due to the cable being
disconnected or the transmission
path being affected by noise.
same line
: Operating as a local station
: Operating as the standby master station
: Operating as the master station
: Error occurrence
: The module is operating normally.
b2
b1 b0
0
0
0
10 Mbps
5 Mbps
2.5 Mbps
625 kbps
156 kbps
MELSEC-Q
Availability
(
: Available,
: Not available)
Online
Offline
Local station
8 - 23