11 COMMUNICATION BETWEEN THE MASTER STATION AND LOCAL
STATIONS

11.3.2 Setting the automatic refresh parameters of the local station

11 - 8
(1) Setting the automatic refresh parameters
Set the automatic refresh parameters according to the procedure below.
(a) Set the refresh device for remote input (RX) to X1000.
(b) Set the refresh device for remote output (RY) to Y1000.
(c) Set the refresh device for remote register (RWr) to D1000.
(d) Set the refresh device for remote register (RWw) to D2000.
(e) Set the refresh device for special relay (SB) to SB0.
(f)
Set the refresh device for special register (SW) to SW0.
POINT
When setting the refresh devices for special relay (SB) and special register (SW) to
SB and SW, respectively, make sure that they do not overlap with device numbers
used in the MELSECNET/H network.
(2) Setting example
A setting example is shown below.
MELSEC-Q
11 - 8